Mitsubishi Electric MELSEC iQ-F Series User Manual page 51

Programmable
Hide thumbs Also See for MELSEC iQ-F Series:
Table of Contents

Advertisement

■FX3 extension module
Product
High-speed counter block
CC-Link system master block
CC-Link system interface block
AnyWireASLINK system master
*1 Connect immediately after the bus conversion module or FX3 extension power supply module.
*2 When using the FX5-CCL-MS as the master station, this block cannot be used.
*3 When using the FX5-CCL-MS as an intelligent device station, this block cannot be used.
*4 Use together with the FX5-ASL-M is not possible.
A MELSEC iQ-F series module cannot be connected on the right side of the FX3 extension module. Place it on the rightmost
side of the system.
Safety extension module
Product
Safety main module
Safety input expansion module
Connect a safety input expansion module on the right side of the safety main module.
Modules cannot be connected on the right side of a safety extension module, so place it on the rightmost side.
When using a safety extension module, an FX3 extension module cannot be used.
When using a safety extension module together with a motion module (FX5-40SSC-G, FX5-80SSC-G), connect a motion
module with a firmware version of "1.001" or later.
Besides an FX5 safety extension module and motion module, when using a safety extension module together with any of the
following intelligent function modules, use the versions specified below.
• FX5-20PG-P: "1.011" or later, FX5-20PG-D: "1.011" or later, FX5-CCLGN-MS: "1.002" or later, FX5-DP-M: "1.001" or later
Conversion module
Product
Connector conversion module
Bus conversion module
Extended extension cable and connector conversion adapter
Product
Extended extension cable
Connector conversion adapter
• To connect to a module of extension cable type
• When the bus conversion module is used together in the same system, connect the extension power supply module (FX5-
1PSU-5V) or powered input/output module immediately after the extended extension cable.
*1 Excluding the extension power supply module (FX5-1PSU-5V) and powered input/output module.
Model
FX3U-2HC
FX3U-16CCL-M
FX3U-64CCL
FX3U-128ASL-M
Model
FX5-SF-MU4T5
FX5-SF-8DI4
Model
FX5-CNV-IF, FX5-CNV-IFC
FX5-CNV-BUSC, FX5-CNV-BUS
Model
FX5-30EC, FX5-65EC
FX5-CNV-BC
*1
, the connector conversion adapter (FX5-CNV-BC) is required.
Maximum number of connectable modules
*1
2
*2
1
*3
1
*4
1
Maximum number of connectable
modules
1
2
Maximum number of connectable
modules
1
1
Maximum number of connectable
modules
1
1
2 SYSTEM CONFIGURATION
2.3 System Configuration Specifications
2
49

Advertisement

Table of Contents
loading

Table of Contents