Page 1
Wireless equipment for Torque wrench Receiver TW-510R TW-510RD TW-510RW TW-510RDW Instruction Manual V1.20 Please use this Instruction manual correctly on reading well. Please keep it carefully to be able to read immediately, when required.
Page 3
To use this product in safety and comfort, (Be sure toread) Thank you very much for purchasing our product. This operation manual contains the precautions necessary for preventing an accident caused by the use in an improper ways. Read it carefully while thoroughly understanding the meanings of pictorial symbols. Using in an improper way while ignoring this pictorial symbol might !...
Page 4
! Warning ■ For handling this machine: ● Do not use this product for the application needing the high reliability related to human lives. ● Do not use this product in a place where it is uncertain about whether or not radio waves reach.
Page 5
This operation manual contains the instruction for “TW-510R”, and also for ”TW-510RW”, ”TW-510RD” and ”TW-510RDW”. Please understand that some parts this manual describes about ”TW-510RW”, ”TW-510RD” and ”TW-510RDW” as an option for value. For the model and available frequency, see the product number seal attached on side of the machine.
Contents 1.General descriptions ........................1 2.Specification ..........................2 3.Names and functions of each part .................... 4 4.Outline of operation ........................6 5.Operational setting ........................8 5-1.To set the ID .......................... 8 5-2.Each setting .......................... 9 5-3.To set the double count prevention time ................. 10 5-4.To set the relay (OUT1 and 2) output time ...............
・ The ID can be set up to 256-type. ・ The built-in Output AC plug outlet is well suited for installing the Receivers with being lined For the “TW-510R”, the following models are available as an option (for value) before shipment. ● TW-510RD :“Diversity type”...
TW-510R 2.Specifications 2.Specifications 2.Specification Items Specifications Remarks TW-510R Diversity type TW-510RD Model 2-unit Receiving type TW-510RW Diversity type+2-unit Receiving type TW-510RDW Available Either 259.55MHz(R2) or 259.65MHz (R4) wave Fixed before shipment frequency Model: Whip antenna: approx. 310mm in overall length...
Page 9
TW-510R 2.Specifications Rotary switch (10-type selective)×2 pcs -For setting output time×1 -For setting double counting prevention time×1 Setting Switch 8-verse DIP switch×3 pcs DIP SW for ID2 is ① For setting ID1×1 only available ② For setting ID2×1 2-unit Receiving ③...
TW-510R 3.Names and functions of each part ①RX1 Antenna connector ⑬RX2 Antenna connector ⑭LED for receiving RX2 (For Diversity model) (For Diversity model) ③Antenna ②Mounting stay ⑥LED for receiving RX1 ④Buzzer ⑤Setting Switch (with Cover) ⑦Power LED ⑪Power cord ⑧Output terminal block OUT1 (For ID1)...
Page 11
TW-510R Names and functions of each part ⑥ LED for receiving RX1 :keeps lighting for 0.2 second when receiving the tightening completion signal through the RX1 antenna. ⑦ Power LED :keeps lighting during Power supply ON. ⑧ Output terminal block 1:Relay turns on when the tightening completion signal of ID1 is received.
・ Double count prevention time setting ・Buzzer sound Effective/Ineffective If you use the “TW-510R” combined with the “TW-510T”, the receivable ID is one type and the single antenna type is available. However, as an option for value, the following three types are also available.
Page 13
TW-510R 4.Outline of operation The next receive restarts after the lapse of double counting prevention time after either OUT1 (ID1) or OUT2 (ID2) turns off. [Outputs from ID1→OUT1] [Outputs from ID2→OUT2] * The “RW””RDW”type can receive two types IDs by setting two types ID, however, cannot receive two types IDs which were simultaneously transmitted from the ”TW-***T”.
TW-510R 5.Operational setting 5.Operational setting To set the “TW-510R”, use the Set switch at center of front side of machine. Loosen the cover screw and remove the cover before setting. SW for double counting SW for each operation prevention time...
TW-510R 5.Operational setting 5-2.Each setting To set the buzzer sounding for “TW-510R”, “TW-510RD”, “TW-510RW” and “TW-510RDW”, use the No.3 of 8-verse DIP Switch (DIPSW3). Be sure to turn off the power supply before changing the set contents. DIPSW3 Functions 1...
TW-510R 5.Operational setting 5-3.To set the double count prevention time You can set the time for disabling the next receiving as the double counting prevention time after a signal is received from “TW-510T” and outputted to OUT1 (or OUT2). Set proper values to prevent the double counting by the “TW-***T”.
Page 17
TW-510R 5.Operational setting TW-510T Transmit signal approx. 0.4sec Relay output time 0.2 to 1.1sec TW-510R OUT Output 0.1 to 1.0sec Double count prevention time ID checking time is delayed (It depends on communicating conditions) Time that does not permit outputting even...
TW-510R 6.Dimensional drawing 6.Dimensional drawing Note:The figure shows “TW-510RD” and “TW-510RDW” type. For “TW-510R” and “TW-510RW” model, BNC connector is only RX1.
TW-510R 7.Installation method 7.Installation method ① Install this machine in the place where it can be easily viewed from the Transmitter (“TW-**T”) and an electric wave can be stably received. If communication is unstable, we recommend you to use the Diversity type antenna (TW-510RD).
TW-510R 8.Troubleshooting 8.Troubleshooting Phenomena Causes and remedies Power does not come Power LED does not light on even after power is turned on. Feed the power ID is not matched Check this machine for the set content, and allow it to be consistent with the ID of “TW-...
Product name / Production No. / Service environment, External devices connected, Operating procedures taken until trouble happens, and Concrete trouble contents HERUTU ELECTRONICS CORPORATION TEL81-53-438-3555 FAX81-53-438-3411...
TW-510R 10.Warranty 10.Warranty Provisions of warranty The provisions of warranty are set forth by us for warranty of the product after shipment so that the product can be used with a sense of security after purchased. In case our product is out of order, we will provide repair or replacement under the provisions of warranty.
Page 23
TW-510R 10.Warranty 8. Troubles occurring due to handling against the use instructions or precautions specified in this operation manual. Initial defects The period within 30 days from the date of shipping the product is defined as the initial defect period for the product. The product will be replaced with a new one or repaired...