LAN Connection Type Andon Receiver WCL-920R Instruction Manual V1.10 Please use this Instruction manual correctly on reading well. Please keep it carefully to be able to read immediately, when required.
WCL-920R 1.OVERVIEW 1-1.Introduction This instruction manual describes the information required for using this product including overview, installation, and operation of this product. Read this manual carefully before using this product. Keep this manual handy so that you can take it out immediately.
4. Because the communication performance is changed depending on the surrounding environment, be sure to confirm the communication is established before installation of this product and then use it. 1-2.Main Unit and Accessories ■Receiver Anntena “MEGWX-467XSAXX-920” x1 Cable Approx. 1.5 m Receiver main unit “WCL-920R” x1 AC adapter “ADB24050” x1...
WCL-920R 1-3.Safety Precautions (Be Sure to Read This) This section describes the matters to be observed in order to prevent harm to the users and other persons and damages to the property. ■ The following marks and displays classify and describe the extent of harm and damage caused by failing to observe the display content and using this product wrongly.
Page 7
WCL-920R ● Do not touch the AC adapter, main body, power cord, and outlet with wet hands. Or the accident such as an electric shock may occur. ● Do not damage the power cord. Short-circuit or heat generation may cause fire or electric shock.
WCL-920R 1-4.Outline receiver (hereinafter called “receiver”). WCL-920R is a LAN connection type Andon The receiver can wirelessly receive in real-time trouble occurrence reports transmitted from the AN920T transmitter installed at the workstations and machines of the production line. In addition, the receiver can externally output the received reports of trouble occurrence via LAN.
WCL-920R 2.Specification 2-1.Radio part specification Item Specification A destination country U.S.A., Canada CFR47(FCC) Part15-247 IC RSS-210 Standard RoHS1 Frequency Band 903MHz~927MHz Modulation Band LoRa Technology Modulation Speed Approx.1170bps Channel Step 1.6MHz Antenna External Sleeve Antenna Communication Half Duplex Method Antenna Power 2.0mW / 70.79mW...
WCL-920R 3.PART NAMES AND DESCRIPTIONS Mounting hole Connector for antenna DC jack LAN Connector Setting switch LED monitor Name Function Connector for Connector for connection to the antenna. (SMA-J Connector) antenna Attach the supplied antenna. Mounting hole of φ4.5 × 4...
WCL-920R 5.Prepare to Start Communication Before use of the receiver, set each receiver according to the use environment. Set the IP address and other required items of the receiver by using Lantronix’s Windows-based software, “Device Installer”. 5-1.Installation of "Device Installer"...
Page 13
WCL-920R To change the IP address, select the address of the X port on the left of the screen. IP assignment button Device details Select IP address to change - Fig. 2 Select IP address of Xport to change - Click “IP assignment button”, and the screen is displayed as shown in Fig.3.
Page 14
WCL-920R Enter the IP address, subnet mask and default gateway. *Before setting an IP address, obtain permission from the network administrator. Click “Next” button. IP settings IP address Subnet mask Default gateway Next - Fig. 4 IP address input screen - Assignment Click “Assignment”...
Page 15
WCL-920R When the setting is completed, the “Exit” button becomes active. It may take some time before the setting is completed. Please wait until the setting is completed. Assignment Task progress Completed Finish - Fig. 6 Input end screen - Click the “Exit”...
Page 16
WCL-920R ■Change Password The WEB screen (Web Manager) inside X port requires user authentication by password. Change the default password in the following procedure. CAUTION Leaving the default password can cause a security risk to the product. Be sure to change the default password.
Page 17
WCL-920R On the “Web Manager” screen in Fig.10, click the “Server” button. “Server” button. - Fig. 10 Web Manager initial screen -...
Page 18
WCL-920R Click the “Server” button, and the “Server Settings” screen in Fig.11 is displayed. ① Set the “Enhanced Password” radio button to “Enable”. ② Enter a new password (up to 16 characters) in the “Telnet/Web Manager Password” field. ③ Enter the same password as ② in the “Retype Password” field.
WCL-920R 6.Settings Use the rotary switch, DIP switches or Ethernet communication command to set the receiver. Details of the settings and methods for changing the settings are as follows: Turn OFF the power of the main unit before changing the settings of the rotary switch or the DIP switch.
Page 20
■Answer back disabled settings When WCL-920R and AN920R are used at the same time, their answerback messages run into each other, and the transmitter may not be able to receive the answerback message. This setting is intended to forcibly disable the answerback of WCL-920R to prevent the answerback messages from running into each other.
WCL-920R 7.Communication Command Function The Ethernet communication command allows information acquisition and device settings of the receiver to be changed. To use the Ethernet communication command function, “Ethernet communication command settings” of the DIP switch, SW1-1 must be valid. 7-1.Information Acquisition Command @?Command<Space>[Param]<Terminal code>...
Page 22
WCL-920R When the information acquisition command terminates normally, the command execution result is as follows: When a response with multiple values is included, a response separated with commas for each data element is returned. <First code>Command<Space><result1>,・・・,<result n><Terminal code> “@?” Fixed (40H,3FH)
Page 23
WCL-920R <Error code> Error group (X) Error number (Y) Meaning 1 No first code (“@”) 2 Non-existent command 3 Character code is included in the set value 4 Command format error 5 Excessive command string length 1 Out of the set value range...
Page 24
Transmission format Execution result Meaning @?Version @?Version 1.00 Software version acquisition @?ModelName @?ModelName WCL-920R Type acquisition @?SerialNumber @?SerialNumber A00001 Serial number acquisition *1: Example when the soft version is 1.00. *2: Example when the serial number is A00001. ■Information acquisition/setting command...
WCL-920R 8.Installation Procedure 8-1.Receiver Installation Communication performance highly depends on the installation environment. Install the receiver as follows. ・ Keep the antenna away from metal sheets or wires, and prevent the antenna from becoming parallel to them. ・ Keep the antenna away from noise sources.
WCL-920R 8-2.LAN connector For the connector use RJ45 type. 1・・・・・・8 The pin specifications are shown in the following table. Pin number Signal name TX+[Transmission data(+)] TX-[Transmission data(-)] RX+[Receiving data(+)] Unused Unused RX-[Receiving data(-)] Unused Unused Please use the cable of the category 5 or higher standard.
Number of Item Contents bytes “@!CallData” ASCII string First code Space Space (20H) “WCL-920R” ASCII string Model Serial number in ASCII Serial number One alphabet letter + 5-digit serial number identifier, starting with “A00001”. Channel settings ASCII string: “00” – ”16”...
WCL-920R 9-2.LED Monitor Check the status of the power supply, wireless communication and wired communication on the LED monitor. Wireless communication LED (Red/Green) Wired communication LED (Red/Green) Power supply LED (Red) LAN connector LED (Orange/Green) ■At power ON The power LED lights up (Red).
Page 29
WCL-920R ■LAN connector Link LED Activity LED Link LED Activity LED LED color Contents LED color Contents Lights off Unconnected Lights off No communication Communicating in half duplex Orange LED light 10Mbps Orange LED light (Turns ON only during communication)
WCL-920R 9-3.Processing at Power ON At power ON, the receiver reads the settings required to work. If the receiver fails to read them, the LED indication and settings may be forcibly initialized. ■Read serial number At power on, the receiver reads the serial number stored in the code flash region.
This regulation (hereinafter referred to as the "Regulation") is for post-shipment warranty provided by HERUTU ELECTRONICS CORPORATION (hereinafter referred to as the "Company") so that you can use the Company's product you have purchased with confidence. The Regulation does not apply to special order products (custom products).
Page 32
This regulation (hereinafter referred to as the "Regulation") shall be applied to paid repair service (hereinafter referred to as the "Service") provided by HERUTU ELECTRONICS CORPORATION (hereinafter referred to as the "Company"). The Regulation does not apply to special order products (custom products).
Page 33
WCL-920R be earlier depending on the availability and procurement status of repair parts. Establishment of contract The contract shall be established when the customer approves the quotation presented by the Company and issues an order form before the end of the repair implementation period.
Page 34
WCL-920R Return of unrepaired product If the Company does not estimate the cost of the Service due to reasons such as being unable to reproduce the failure, it will return the Product for repair to the customer. In addition, if the customer does not place an order within three months from the date of creation of the...