Page 1
MAKING MODERN LIVING POSSIBLE Installation Guide ECtemp 530 Electronic Thermostat www.EH.danfoss.com...
Page 2
Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC)
..Introduction ECtemp 530 is an electronic thermostat provided with a 2- pole switch and a wire sensor to measure and control the desired floor temperature. It can be either flush-mounted (standard) or surface-mounted (using special box).
ECtemp 530 Type Storage temperature -20 to +65°C IP class Protection class Class II - Dimensions 85 x 85 x 36mm Weight The product complies with the EN/IEC Standard "Automatic electrical controls for household and similar use": ▪ EN/IEC 60730-1 (general) ▪...
ECtemp 530 Please also note the following: ▪ The installation of the thermostat must be done by an authorized and qualified installer according to local regulations. ▪ The thermostat must be connected to a power supply via an all-pole disconnection switch.
Page 7
ECtemp 530 Note: A floor sensor enables a more accu- rate temperature control and is recom- mended in all floor heating applications and mandatory under wooden floors to reduce the risk of over-heating the floor. ▪ Place the floor sensor in a conduit in an appropriate place where it is not exposed to sunlight or draft from door openings.
Page 8
ECtemp 530 Follow the steps below to mount the thermostat: 1. Open the thermostat: ▪ Press the release tab in the bottom of the ther- mostat using a flat object. ▪ Carefully detach the front cover. ▪ Carefully detach the frame.
Page 9
ECtemp 530 2. Connect the thermostat according to the connection diagram. LOAD LOAD Mains Max. Load -5°C 220-240V~ 15 (1) A IP31 -10T30 D530 By connecting an external timer to the terminal marked by a moon symbol (and by using for example...
ECtemp 530 3. Mount and reassemble the thermostat. ▪ Fasten the thermostat to a socket or an exterior wall box by driving the screws through the holes in each side of the thermostat. ▪ Install the frame and front cover in the reverse or- der of disassembly.
Page 11
ECtemp 530 Note: Please be aware of the following: ▪ The floor temperature is measured where the floor sensor is placed. ▪ The temperature of the bottom of a wooden floor can be up to 10 degrees higher than the top.
Page 15
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.