Disposal Instruction ....14 Introduction ECtemp 610 is an IP44 electronic thermostat to be installed directly on the wall. It is provided with a 2-pole switch and a wire sensor to control the desired temperature.
ECtemp 610 Technical Specifications Operation voltage 220-240 V~, 50 Hz Standby power consumption Max. 0,93 W Relay: Resistive load Max 10 A / 2300 W @ 230 V Inductive load cos φ= 0,3 max 1A Sensing units NTC 15 kOhm at 25 °C Sensing values: 0 °C...
ECtemp 610 Dimensions 100 x 69,5 x 45 mm Weight 165 g The product complies with the EN/IEC Standard “Automatic electrical controls for household and similar use”: • EN/IEC 60730-1 (general) • EN/IEC 60730-2-9 (thermostat) Safety Instructions Make sure the mains supply to the thermostat is turned off before installation.
ECtemp 610 Mounting Instructions Please observe the following placement guidelines: • The thermostat can be placed both indoors and outdoors. • Place the thermostat on a wall, pole, steel/wooden plate or pipe. In wet rooms, place the thermostat ac- cording to local regulation on IP classes.
Page 7
ECtemp 610 Follow the steps below to mount the thermostat: Open the thermostat: • Set adjustment button to minimum temperature. • Loosen the 2 screws and open the front cover. Installation Guide...
Page 8
ECtemp 610 Fasten the thermostat: • Drive the screws through the holes in the bottom corners of the thermostat. • Seal the holes with the enclosed screw stopper to maintain the density. Installation Guide...
Page 9
ECtemp 610 Connect the thermostat according to the connection diagram. • Heating: (L-main, N-main, L-load, NO (normally open) - load). • Cooling: (L-main, N-main, L-load, NC (normally closed) - load). The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector.
Page 10
ECtemp 610 Install sensor using the supplied sensor cable - NTC 15 kΩ @ 25 °C. • Press out the blanket located at the bottom of the thermostat and insert the seal nipple. • Connect sensor to terminals 6+7. The sensor cable can be extended up to 50 m with 1,5 mm²...
All work will be invoiced in full if Danfoss is required to inspect or repair faults that have arisen as a result of any of the above. The Danfoss warranty shall not extend to products which have not been paid in full. Danfoss will, at all times, provide a rapid and effective response to all complaints and inquiries from our customers.
Need help?
Do you have a question about the ECtemp 610 and is the answer not in the manual?
Questions and answers