Danfoss ECtemp 532 Installation Manual page 7

Advertisement

Danfoss ECtemp 532
• Place the floor sensor in a conduit in an appropriate
place where it is not exposed to sunlight or draft from
door openings.
• Equally distant and >2cm from two heating cables.
• The conduit should be flush with the floor surface -
countersink the conduit if necessary.
• Route the conduit to the connection box.
• The bending radius of the conduit must be min 50mm.
Installation Guide
Do not place the thermostat on the inner
side of an exterior wall.
Always install the thermostat at least 50 cm.
from windows and doors.
Do not place the thermostat in a way that it
will be exposed to direct sunlight.
Note: A floor sensor enables a more
accurate temperature control and is recom-
mended in all floor heating applications
and mandatory under wooden floors to
reduce the risk of over-heating the floor.
7