Starting And Operating; General Notes On Starting - PI P-88 Series User Manual

Table of Contents

Advertisement

6 Starting and Operating

6
Starting and Operating
In this Chapter

General Notes on Starting ........................................................................................................... 31

Determining the Operating Parameters ...................................................................................... 35
Operating the P-88x/P-08x .......................................................................................................... 39
Discharging the P-88x/P-08x ........................................................................................................ 39
Short-Circuiting the P-88x/P-08x ................................................................................................. 40
6.1
General Notes on Starting
CAUTION
Dangerous voltage in piezo actuators during operation!
During operation, the piezo actuator carries voltages of up to 120 V (P-88x models) or 100 V
(P-08x models). Touching the piezo actuator can lead to minor injuries from electric shock.
 Do not touch the piezo actuator during operation.
 Before startup, insulate the piezo actuator electrically from the surrounding mechanics to
prevent direct or indirect contact with live parts. Pay attention to the clearances and
creepage distances required for the operating voltage as well as the standards applicable
to your application.
CAUTION
Risk of electric shock if the protective earth conductor is not connected!
The system into which the piezo actuator is integrated (e.g., housing or surrounding
mechanical system) must be connected to a protective earth conductor. If the protective earth
conductor is not or not properly connected, touching the system in which the piezo actuator
was incorporated can lead to minor injury from electric shock in the case of a malfunction.
 Before startup, connect the overall system to a protective earth conductor in accordance
with the applicable standards.
 Do not remove the protective earth conductor during operation.
 If the protective earth conductor has to be temporarily removed (e.g., for modifications),
reconnect the overall system to the protective earth conductor before restarting.
P-88x/P-08x Piezo Actuator
PZ259E
Version: 1.1.0
31

Advertisement

Table of Contents
loading

Table of Contents