Perform the Initial System Configuration
The following list will deny access to IP address 10.1.1.0, but permit access to all others:
deny 10.1.1.0
permit any
If no entry in the assigned Access Control List matches the connection, or if the Access Control List is
empty, the default action is deny.
To create the access control lists, complete the following steps:
SUMMARY STEPS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
DETAILED STEPS
Enter the Access Control Lists configuration menu.
Step 1
Would you like to enter the Access lists configuration menu? [no]:y
Type
The Access Control Lists configuration dialog begins.
You have the option of creating or modifying Access Control Lists, or skipping this section and
Step 2
proceeding directly to assign the existing ACLs to the desired management interfaces.
Would you like to create new Access lists or modify existing lists? [no]: y
If you choose not to create or edit Access Control Lists, skip to .
Step 3
Type the number of the Access Control List to be configured (1 through 99) and press Enter .
Note that there is no default for this parameter.
Step 4
Begin adding entries to the selected list.
Indicate whether this entry is permitted access or denied access.
Type the IP address to be added to this list, and press press Enter.
Step 5
Note that there is no default for this parameter.
Enter IP address or the word 'any' to denote any IP address:
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
4-14
Enter the Access Control Lists configuration menu.
You have the option of creating or modifying Access Control Lists, or skipping this section and
proceeding directly to assign the existing ACLs to the desired management interfaces.
Type the number of the Access Control List to be configured (1 through 99) and press Enter .
Begin adding entries to the selected list.
Type the IP address to be added to this list, and press press Enter.
If you entered a specific IP address, enter the wildcard bits to define a range of IP addresses and
press Enter . (See
Entry Formats, page
The maximum number of entries in an ACL is 20.
When all entries are added to one list, you are asked whether you would like to create another ACL.
You may define up to 99 ACLs.
Restrict IP access to the SCE 1000 by assigning the appropriate ACL.
Restrict Telnet access to the SCE 1000 by assigning the appropriate ACL.
and press press Enter.
y
To permit access press press Enter.
To deny access type
and press press Enter.
n
Chapter 4
Connect the Management Interfaces and Perform Initial System Configuration
4-13.)