Plumbing Fixture - Nibe DRAZICE TO - 20.1 Operating And Installation Manual

Table of Contents

Advertisement

VOLUME
MAX OPERATING OVERPRESSURE IN THE TANK
ELECTRICAL CONNECTION
INPUT
EL. PROTECTION
MAX OPERATING TEMPERATURE OF HOT WATER
(HW)
RECOMMENDED HOT WATER (HW)
TEMPERATURE
HEIGHT OF THE HEATER
HEATER DIAMETER
MAX WEIGHT OF THE HEATER WITHOUT WATER
TIME OF EL. HEATING FROM 10°C TO 60°C *
MIXED WATER V40
LOAD PROFILE
ENERGY EFFICIENCY CLASS
ENERGY EFFICIENCY
ANNUAL CONSUMPTION OF ELECTRIC ENERGY
If the hot water heater is mounted in a tight, small space, or in an intermediate ceiling, etc., you
have to make sure that the connecting side of the appliance (connections to water supply, area
for electric plugging) remained accessible and no heat accumulation occurs. Free space of up to
600 mm from the bottom edge of the heater has to be available under the heater.
When mounted directly under the ceiling, the distance from the ceiling has to be 100 mm
at least
2.3

PLUMBING FIXTURE

The safety valve can be mounted both in vertical and horizontal position in the indicated
direction of cold water flow. Safety valve is mounted on the cold water inlet identified with
a blue ring.
The heater must be equipped with a membrane, spring-loaded safety valve. Safety valves with
fixed pressure settings from the manufacturer are used for the assembly. Each individually
lockable heater must be fitted with a cap on the cold water inlet, a test valve or a stopper to
check the operation of the check valve, with a drain valve, a check valve and a safety valve
(Figure 3). The safety valve with a check valve is supplied with the heater.
l
bar
-
W
-
°C
°C
mm
mm
kg
hours
l
-
-
%
kWh
Table 1
TO 20.1
20
6
1/N/PE ~ 230 V / 50 Hz
2200
IP 44
80
60
585
516
12
0.5
26.14
S
A
38
485
- 7 -