For Your Safety

Strictly follow the Instructions for Use
Any use of the oxygen self-rescuer requires full understanding and strict
observation of these instructions.
The oxygen self-rescuer is only to be used for purposes specified here.
Maintenance
The oxygen self-rescuer must be inspected and serviced regularly by
trained service personnel.
Repair and general overhaul of the oxygen self-rescuer may only be carried
out by trained service personnel.
We recommend that a service contract be obtained with Dräger Safety and
that all repairs also be carried out by them.
Only authentic Dräger spare parts may be used for maintenance.
Accessories
Only use accessories mentioned in the order list.
Liability for proper function or damage
The liability for the proper function of the oxygen self-rescuer is irrevocably
transferred to the owner or operator to the extent that the oxygen self-
rescuer is improperly serviced or repaired by personnel not employed or
authorized by Dräger Safety or if the oxygen self-rescuer is used in a
manner not conforming to its intended use.
Dräger Safety cannot be held responsible for damage caused by non-
compliance with the recommendations given above.
The warranty and liability provisions of the terms of sale and delivery of
Dräger Safety are likewise not modified by the recommendations given
above.
Disposal
Used or opened units have to be disposed professionally, since the
reaction between the air humidity and the used chemical can generate an
aggressive base.
Dräger Safety AG & Co. KGaA

Description

Oxy K 30 HW/HS is an oxygen self-rescuer, independent of the ambient
air, with a closed to-and-fro breathing system which uses chemically-bound
oxygen and a fire escape hood.
Oxy K 30 HW/HS has a nominal duration of 30 minutes (at the breathing
rate of 35 L/min according to DIN 58 639). The operating period can be
significantly extended depending on the users breathing rate.
The Oxy K-Series of oxygen self rescue devices conform to DIN 58 639
and meet the requirements of EC Council Directive PPE (89/686/EC).
The Notified Body EXAM BBG Prüf- und Zertifizier GmbH
Zertifizierungsstelle für Atemschutz, with Reference no. CE 0158 has
conducted EC type examination and is involved in
Dräger Safety AG & Co. KGaA Quality Management System control.

Intended Use

Oxy K 30 HW/HS is intended for emergency escape from areas filled with
smoke or toxic gases or lacking oxygen.
Restriction:
Oxy K 30 HW/HS is only suitable for use in the temperature classes
T1, T2, T3 and T4.
CAUTION:
Due to the possible presence of oxygen in the hood, the user must
avoid direct contact to flames or sparks when carrying the
Oxy K 30 HW/HS. The presence of oxygen in the hood increases fire
hazards, which can result in serious injuries or even death.
If the emergency exit is completely blocked by flames and sparks,
direct contact can to a large extent be avoided by covering the hood
with ones own body.
Follow the advice given in these Instructions for Use.
Oxy K 30 HW/HS can save your life!
10

Carrying Method

Oxy K 30 HS
Everyday carried on the shoulder.
Other methods are possible, such as
transport in a vehicle
on the chest with additional chest strap
in an emergency on the chest.
Before Placing the Oxygen Self-Rescuer into
Service
Oxy K 30 HS
The Oxy K 30 HS has to be weighed upon being delivered.
When weighing the oxygen self-rescuer, detach the harness.
The measured weight has to be compared with the weight on the metal
plate.
CAUTION:
If the weight is more than 6 grams off the listed weight, the oxygen
self-rescuer has to be discarded.
Before placing the oxygen self-rescuer
into service, the customer has to mark
the oxygen self-rescuer with the dates of
the inspection intervals on the metal
plate. The metal plate is on the backside
of the oxygen self-rescuer.
The use of letter punches is not
allowed. Dräger recommends
engraving or etching.
There are six open fields on the
metal plate.
st
1
field –date of delivery– fill in month and year
(e.g. 07/03)
nd
st
2
field –1
Inspection– fill in date of delivery plus three years
(e.g. 07/06)
rd
nd
3
field –2
Inspection– fill in date of delivery plus five years
(e.g. 07/08)
th
rd
4
field –3
Inspection– fill in date of delivery plus seven years
(e.g. 07/10)
th
th
5
field –4
Inspection– fill in date of delivery plus nine years
(e.g. 07/12)
th
6
field –End of Lifetime– fill in date of delivery plus ten years
(e.g. 07/13)
Furthermore you will find on the metal plate the following dates filled in by
the manufacturer:
date of manufacturing
serial number
part number
weight
CE Marking
Product Standard
Designation
st
Date of
Date of delivery
1
. Inspection
manufact.
Serial Number
nd
2
. Inspection
Fill out
Part Number
by
customer
rd
3
. Inspection
Weight
th
End of Lifetime
4
. Inspection
CE 0158
DIN 58639

Advertisement

Table of Contents
loading