1.3 Introduction
to PMM 9010
1.4 Instrument Items
1.5 Optional
accessories
1.6 Other accessories
1-2
General Information
PMM 9010 is a powerful EMI receiver, fully CISPR 16-1-1, to measure
conducted and radiated interferences from 10 Hz up to 30 MHz, or even up
to 3 GHz when matched with PMM 9030 extension unit (optional). All
measurements performed by the PMM 9010 are according to the most
accepted standards like: IEC, CISPR, EN (EuroNorm), FCC, VDE, ....
Thanks to its built-in tracking generator, PMM 9010 is also suitable for
designing, characterizing and testing RF filters, transducers and other
components.
The PMM 9010 has been designed adopting an innovative philosophy
made possible only in the recent years by the availability of superior
technology components. This equipment is fully digital but the input
preselector and attenuator – and, of course, the output stage of the internal
reference tracking generator - and therefore combines into a pure EMI
Receiver and Signal Analyzer the precision and accuracy of a numeric
approach, with flexibility and user friendly approach typical of a modern
instrument.
PMM 9010 includes the following items:
• EMI Receiver from 10 Hz up to 30 MHz
• BP-01 Li-ion battery pack;
• External power supply/battery charger;
• Flexible black cover/accessories holding;
• BNC-BNC coaxial cable 2m length;
• RS232 cable, 2m;
• USB cable, 2m;
• Operating manual;
• PMM 9010 Utility Software on CD;
• Certificate of Compliance;
• Return for Repair Form.
PMM 9010 can be used with several optional accessories, the most
common being the following:
• PMM 9030 EMI Signal Analyzer 30 MHz - 3 GHz;
• 9010-BTA Serial Bluetooth Adapter;
• Single Channel Click option;
• L1-150: Single line LISN, 150A (50Ω//1 Ω+5µH);
• L2-16: Two lines, Single phase, 16A LISN, (50Ω//5 Ω+50µH);
• L3-32: Four lines, 3-phase, 32A LISN, (50Ω//5 Ω+50µH);
• L3-64: Four lines, 3-phase, 64A LISN, (50Ω//5 Ω+50µH);
• L3-100: Four lines, 3-phase, 100A LISN, (50Ω//5 Ω+50µH);
• L3-500: Four lines, 3-phase, 350A LISN, (50Ω//5 Ω+50µH);
• SHC-1: 35 dB CISPR Voltage probe, 1500Ω;
• SHC-2: 30 dB CISPR Voltage probe, 1500Ω;
• RA-01: Rod Antenna (10 kHz – 30 MHz).
Of course, the PMM 9010 can be used with other accessories available on
the market, like:
• LISNs, any type;
• Antennas and Loops;
• Near Field Probes;
• Various TEM/GTEM Cells.