How To Set The Conditions For Logging Danger Targets; How To Playback The Log - Furuno FMD-3100 Operator's Manual

Electronic chart display and information system ecdis
Hide thumbs Also See for FMD-3100:
Table of Contents

Advertisement

19.5.1

How to set the conditions for logging danger targets

The operator may set Closest Point of Approach (CPA), Time to CPA (TCPA) and Log
interval for viewing dangerous TT and AIS targets on the ECDIS display.
1. Open the menu and select the [Danger Targets] page from the [Danger Target]
menu.
2. Set how often to record dangerous TTs and AIS target with [Log interval]. The set-
ting range is 1 to 100 (min.).
19.6

How to Playback the Log

The log can be played back to check ship's movements within a given time frame. If
an AMS is connected, deactivate it to enable playback.
1. On the Status bar, click the [OTHERS] and [Playback] buttons. The message "If
you use playback function, you cannot use other function before ECDIS restarts."
appears. Click the [OK] button to proceed. The window shown below appears.
2. Select the date to playback. Log data is stored by the day. To play back data in
the current month, click a day in the calendar. For other dates, click the [] or []
button to select the month and then click a day in the calendar. To playback the
current day, click the button at the top of the screen.
19. RECORDING FUNCTIONS, PLAYBACK FUNCTIONS
Click to playback data
of current day.
19-9