022
Fan3 No
Rotation
023
Fan4 No
Rotation
024
RS485 Communi-
cation Timeout
025
No Signal
026
Sentence Syntax
Error
027
Main Monitor COM
Timeout
028
Sub Monitor
COM Timeout
030
Sensor Adapter 1
COM Timeout
031
Sensor Adapter 2
COM Timeout
032
Sensor Adapter 3
COM Timeout
033
Sensor Adapter 4
COM Timeout
Default
Meaning
Warning
For MU-231: Connected to
COM2 (Sub Monitor).
Fan3 rotation speed is be-
low threshold.
Warning
For MU-190: Connected to
COM2 (Sub Monitor).
Fan4 rotation speed is be-
low threshold.
Caution
For MU-190/231: Connect-
ed to COM2. There has
been no communication
from processor unit through
RS485 for 180 seconds.
(No communication implies
incomplete sentence or
checksum error.)
Caution
For MU-190/231: Connect-
ed to COM2. There has
been no signal continuously
for 60 seconds.
Caution
For Sub monitor, connected
to COM2, value of external-
ly input sentence is out of
range defined by sentence.
Caution
Communication with MU is
interrupted. 60 seconds tim-
eout.
Caution
Communication with MU is
interrupted. 60 seconds tim-
eout.
Caution
Communication error with
No.1 sensor adapter is de-
tected. 30 seconds timeout.
No.1 sensor adapter is
turned off, or there is a prob-
lem with network.
Caution
Communication error with
No.2 sensor adapter is de-
tected. 30 seconds timeout.
No.2 sensor adapter is
turned off, or there is a prob-
lem with network.
Caution
Communication error with
No.3 sensor adapter is de-
tected. 30 seconds timeout.
No.3 sensor adapter is
turned off, or there is a prob-
lem with network.
Caution
Communication error with
No.4 sensor adapter is de-
tected. 30 seconds timeout.
No.4 sensor adapter is
turned off, or there is a prob-
lem with network.
APPENDIX 4 ALERT LIST
Remedy
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence..
Check the connection of
brightness control cable.
Check the connection of
video cable.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
Check the connection with
the monitor.
Check the connection with
the monitor.
Check the connection with
No.1 sensor adapter and
network.
Check the connection with
No.2 sensor adapter and
network.
Check the connection with
No.3 sensor adapter and
network.
Check the connection with
No.4 sensor adapter and
network.