102-xx
Processor error
103-xx
DMA controller failed
104-xx
Interrupt controller failed
105-xx
Port error
106-xx
Keyboardcontroller self-test failed.
107-xx
CMOS RAM test failed
108-xx
CMOS interrupt test failed
109-xx
CMOS clock failed
110-xx
Reprogrammable timer test failed
111-xx
Refresh detect test failed
112-xx
Speed test failed
113-01
Protected mode test failed
114-xx
Speaker test failed
199-xx
Installed devices test failed
Return to top
Memory Error Codes
Error Code: Description:
Run
Setup
and retest.
1.
Replace the
processor
2.
The following step applies to error code
103-xx through 106-xx:
Replace the
system
board.
The following steps apply to error
code: 107-xx through 109-xx:
Replace the battery/ clock module
1.
and retest.
Replace the
system board
2.
retest.
The following steps apply to error codes
110-xx through 113-xx:
Replace the
system board
Verify the speaker connection.
1.
Replace the
system board
2.
retest.
Check system configuration.
1.
Verify cable connections.
2.
Check switch settings.
3.
Run
Compaq
Utilities.
4.
Replace the
system board
5.
retest.
Recommended Action:
and retest.
and
and retest.