Key Switch (Optional); Display Mode; Jumper Settings - CAMDEN CX-DE1220 Installation Instructions Manual

Double door (main and tandem lock)
Table of Contents

Advertisement

NOTE:
1) All field-wiring
to the unit shall
not exceed 98.5 ft
(30 m).
2) All external
this J10 jumper only if Fire Panel or Smoke Detection system is connected to the (Fire P) terminal.
power sources shall
be UL Listed with
Class 2, power-
limited output.
Built-in Key Switch
(Reset & Bypass)
CX-DESPK
Ex-Spkr
Remote Speaker
(Optional)
Power Supply
Built-In
Key Switch
(Reset &
Bypass)
External Speaker

Display Mode

Mode: 15 and 30 Seconds
Door armed and locked in 15 or 30 seconds mode
Mode: Bypass
Door unlocked (Either Bypass or R-exit)
Mode: Unlocked (LED Blinking)
Door unlocked & alarm sounding until reset
D
De
l l e
y a a
y E
E
g g
e re r
s s s
s E
E
(Intended use on Double Leaf Door)
Ex-Spkr
Pwr
Pwr
Fire P
Lock
+
-
+
-
+
C NC
CM-120i Keypad
Pwr
Pwr
Fire P
Lock
Grn Rly
C NC
NO C NC
(Optional)
Push Bar (Optional)
Display Mode
Mode: 15 and 30 Seconds
Door armed and locked in 15 or 30 seconds mode
Mode: Bypass
Door unlocked (Either Bypass or R-exit)
Mode: Unlocked (LED Blinking)
Power Supply
Door unlocked & alarm sounding until reset

Jumper Settings

a
P
g
e
4
this J10 jumper only if Fire Panel or Smoke Detection system is connected to the (Fire
e e l l
t t c c
o ro r
m m
a a
g g
n n
e e
c i i t t
c L k c c
o o L k I
Pwr
Ex-Spkr
R-Exit
Grn Rly
Red Rly
Ex-Trig
Reset
-
NO C NC
NO C NC
NO C
NO C
NO C
Built-In
Key Switch
(Reset &
Bypass)
External Speaker
R-Exit Bypass
Red Rly
Ex-Trig
Reset
NO
NO C NC
NO C NO C NO C NO C
Aux RLY
COM
NO
Main RLY
COM
GND
+12V
Power Supply
CX-DE1201
CM-120i Keypad
(optional)
ATS
DPS
BOND-S
no
c
nc
no c nc
no c nc
ATS
CM-1200
Key Switch
(Optional)
AC Main
3 Core Cable
Jumper J10 (Fire Panel Input)
Power Supply
Installed: Factory default setting
Uninstalled: Only if a dry contact (NC) from a
fire alarm panel or smoke
detector system is connected to
the "Fire P" terminals.
CX-DE1220 Double Door (Main and Tandem Lock)
I N S TA L L AT I O N I N S T R U C T I O N S
n n I
t t s s
l l l l a a
t t a a
o o i i
n
n
CX-DE1200
Pwr
Fire P
Lock
Grn Rly
Red Rly
Ex-Trig
C NC
NO C NC
NO C NC
NO C NO C NO C NO C
ON
ON
DI P
DI P
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
J10
ATS
Bypass
DPS
Bond-S
NO C
NO C NC NO C NC
NO C NC
Push Bar (Optional)
ON
DIP
1 2 3 4 5 6 7 8
J10
DPS
ATS
Bond-S
NO C NC NO C NC
NO C NC
CM-1200
Key Switch
(Optional)
CM-1200
Key Switch
(Optional)
NO
AUX Rly
COM
NO
AC Main
Main Rly
COM
GND
+12V
EX-TRIG
LOCK
PW R
no c
+
-
+
-
NO
COM
Fire Panel
2 Core Cable
J10
R-Exit Bypass
Reset
DPS
Bond-S
NO C NC NO C NC
NO
AUX Rly
COM
NO
Main Rly
COM
GND
+12V
CM-120i Keypad
(optional)
NO
COM
Fire Pane
3 Core Cable
2 Core Cab
Power Supply
Push Bar (Ex-Trig)
Keypad
Page 5 of 10