CX-DE1220 Double Door (Main and Tandem Lock)
I N S TA L L AT I O N I N S T R U C T I O N S
Door Frame
Armature
Tandem
Lock
5. INSTALLATION CONCEPT AND ACCESSORIES
Seven configuration versions are available to be compliant to regional jurisdictions.
Delay Release Time
Models
Fixed
CX-DE1200-N1
CX-DE1200-N2
15
CX-DE1200-N3
30
CX-DE1200-N4
15
CX-DE1200-B1
15
CX-DE1200-B2
30
CX-DE1200-B3
15
BOCA Compliance
Manual Reset: Is achieved by authorized personnel closing the door after an alarm and actuating the integral reset key switch
or by momentarily closing a contact connected to the remote RESET terminal.
Automatic Reset: Reset will automatically be initiated once the door has been opened, then closed and remains closed for
30 consecutive seconds.

Dip Switch Settings

Release Time
Nuisance Time
R-Exit Time
Trigger type
Start-Up State
Door POS Alarm
Anti Pass Back
Page 4 of 10
Main Lock
Nuisance Delay
(Seconds)
Selectable
Fixed
15 or 30
0
N# = NFPA Compliance
Warning Type
Languages
Voice Type
Door Frame
Reset After Alarm
(Seconds)
Selectable
Selectable
1 or 2
0 or 1
0 or 1
0 or 1
0 or 3
Auto / Manual
0 or 3
Auto / Manual
Auto / Manual
B# = BOCA Compliance
WARNING!
!
Contact authority having jurisdiction for approval prior to
selecting release time, nuisance time and start-up settings.
Cable Installation:
1. Install supplied Route cable through the door frame
2. Connect wires to the main lock and to the tandem lock
Cable Route
Through Frame
Tandem
Lock
Main Lock
Lock Status on Power-Up
Fixed
Fixed
Manual
Locked / Unlocked
Locked / Unlocked
Manual
Locked / Unlocked
Manual
Manual
Unlocked
Locked / Unlocked
Locked / Unlocked
Locked / Unlocked
Selectable