4 Installation
CAUTION! Be extremely careful
A
not to dent or damage the piping
while bending them away from
the unit. Any dents in the piping
will affect the unit's performance.
Step 5: Connect drain hose
By default, the drain hose is attached to the
lefthand side of unit (when you're facing the back
of the unit). However, it can also be attached to
the right-hand side. To ensure proper drainage,
attach the drain hose on the same side that your
refrigerant piping exits the unit. Attach drain hose
extension (purchased separately) to the end of
drain hose.
• Wrap the connection point firmly with Teflon
tape to ensure a good seal and to prevent leaks.
• For the portion of the drain hose that will remain
indoors, wrap it with foam pipe insulation to
prevent condensation.
• Remove the air filter and pour a small amount of
water into the drain pan to make sure that water
flows from the unit smoothly.
C
Make sure to arrange the drain
hose according to the follo.wing
figures.
Split Type Air Conditioner / User Manual
CORRECT
CORRECT
Make sure there are no kinks
Make sure there are no kinks
or dent in drain hose to ensure
or dent in drain hose to ensure
proper drainage.
proper drainage.
NOT CORRECT
NOT CORRECT
Kinks in the drain hose will
Kinks in the drain hose
will create water traps.
create water traps.
Plug the unused drain hole. To
prevent unwanted leaks you
must plug the unused drain
hole with the rubber plug
provided.
4.2.3 Before performing any electrical
work, read these regulations
1. All wiring must comply with local and national
electrical codes, regulations and must be
installed by a licensed electrician.
2. All electrical connections must be made
according to the Electrical Connection Diagram
located on the panels of the indoor and outdoor
units.
3. If there is a serious safety issue with the power
supply, stop work immediately. Explain your
reasoning to the client, and refuse to install the
unit until the safety issue is properly resolved.
NOT CORRECT
NOT CORRECT
Kinks in the drain hose
Kinks in the drain hose
will create water traps.
will create water traps.
NOT CORRECT
NOT CORRECT
Do not place the end of the
Do not place the end of the
drain hose in water or in
drain hose in water or in
containers that collect water.
containers that collect water.
This will prevent proper
This will prevent proper
drainage.
drainage.