When troubles occur, please check the following points before contacting a repair company.
Problem
Possible Causes
Temperature setting may be higher
than ambient room temperature
The heat exchanger on the indoor or
outdoor unit is dirty
The air filter is dirty
The air inlet or outlet of either unit is
blocked
Doors and windows are open
Poor Cooling
Excessive heat is generated by
Performance
sunlight
Too many sources of heat in
the room (people, computers,
electronics, etc.)
Low refrigerant due to leak or long-
term use
SILENCE function is activated
(optional function)
48 / 184 EN
Solution
Lower the temperature setting
Clean the affected heat exchanger
Remove the filter and clean it according to instructions
Turn the unit off, remove the obstruction and turn it
back on
Make sure that all doors and windows are closed
while operating the unit
Close windows and curtains during periods of high
heat or bright sunshine
Reduce amount of heat sources
Check for leaks, re-seal if necessary and top off
refrigerant
SILENCE function can lower product performance
by reducing operating frequency. Turn off SILENCE
function.