Menu 1 - Changing the access password- type # 01
Type the new password (maximum 6 digits) and confirm with ' ' (e.g. 112233 ).
The keypad will sound a 3-second long beep. The password has been changed
N.B.: The password allows access to the keyboard management functions.
If you lose the password you will have to send the keyboard back to the manufacturer
to be reset.
type
Menu 2 - Backlighting setting parameters - type # 02
0
Backlighting level - Maximum
1
Backlighting level - Medium
2
Backlighting level - Minimum
type
Menu 3 - Backlighting activation mode - type # 03
0
Backlighting mode - Always OFF
1
Backlighting mode - Active on user event
2
Backlighting mode - Always ON
type
Menu 4 - Buzzer intensity setting - type # 04
0
Buzzer intensity - High sound setting
1
Buzzer intensity - Low sound setting
type
Menu 5 - Buzzer activation mode - type # 05
0
Buzzer activation mode - OFF
1
Buzzer activation mode - ON (sounds each time a key is pressed)
2
Buzzer activation mode - ON (sounds only for confirmation/error)
Menu 6 - Light sensor calibration - type # 06
Using this function it is possible to calibrate the intervention threshold
for the ambient light sensor. To start the procedure you must reinsert the
access password and confirm by pressing .The keypad will carry out
a 5 second countdown indicated by the sounding of the buzzer during
which time the operator will have to remove his hand from the vicinity of
the keypad, e.g. after typing # 06 , type "password ".
Menu 7 - Proximity sensor calibration - type # 07
default
Using this function it is possible to calibrate the proximity sensor. The
keypad will carry out a 5 second countdown indicated by the sounding
of the buzzer during which time the operator will have to remove his hand
from the vicinity of the keypad. To start the procedure you must reinsert
default
the access password and confirm by pressing , e.g. after typing # 07
, type "password ".
type
Menu 8 - Select DKS address - type # 08
1st DKS device address
0
2nd DKS device address
1
default
3rd DKS device address
2
Menu 9 - Return to factory settings - type # 09
default
Using this function you can reset the device to its default factory settings
meaning all the parameters modified in the SERVICE menu will be reset. To
start the procedure you must reinsert the access password and confirm by
pressing . e.g. after typing # 09 , type "password ".