V&T V5 Series User Manual page 37

Table of Contents

Advertisement

Function
code
Function code name
number
Terminal Up/Dn lowest
H0.35
frequency regulation
Terminal Up/Dn
H0.36
superposition step
Terminal Up/Dn
H0.37
superposition delay
H1.00
Position control enable
H1.01
Reset position pulse high
H1.02
Reset position pulse low
Current pulse high
H1.03
Current pulse low
H1.04
Pulse ratio
H1.05
current position
H1.06
Forward maximum position 10000
H1.07
H1.08
Reverse maximum position 60000
Forward stop position
H1.09
H1.10
Reverse stop position
H1.11
Maximum speed
H1.12
Forward deceleration
H1.13
Reverse deceleration
Normal position
H1.14
Note: The position calculation is only valid under the V6 series, and a PG feedback card is required.
The position calculation and the automatic stop function of the arrival position are only used as auxiliary functions. The mechanical
deceleration limit, weight limit, cam limit, etc. of the lifting machinery must not be cancelled.
There is an error in the position calculation. Please make sure that each cycle of the operation needs to go through the reset position
and reset the position to avoid the error of position calculation.
In order to ensure the position calculation function is normal, please regularly maintain and maintain the inverter and motor encoder.
H2.00
EX-DT01 card enabled
high performance crane special inverter User Manual
Factory
Setting range
setting
5.00
0.00~50.00
0.50
0.00~10.00
0.050
0~60.000
Position control function
0000
0000~FFFF
0000
0000~FFFF
0000
0000~FFFF
0000
0000~FFFF
0000
0000~FFFF
1000
0~65535
0
0~65535
0~65535
0~65535
6000
0~65535
64000
0~65535
300
0~65535
40
0~65535
40
0~65535
0
0~1
EX-DT01 expansion card function
0
0~1
Chapter 4 Crane special inverter parameters lists
Unit Property
running command to maintain the given frequency.
1: The frequency is too low and then close the
running command to maintain the lowest frequency.
Hz
Hz
Only valid if H0.34=3
s
0: The position calculation is invalid, and the
automatic stop is invalid after the position is
reached.
1: Position calculation is valid, automatic stop is
/
invalid after reaching the position
5: The position calculation is valid, and the
automatic stop is also effective after reaching the
position.
/
The multi-function input terminal is set to function
No. 33. Once the terminal is closed, the pulse
signal is reset to the values set by H1.01 and H1.02
/
for the initial setting position and for eliminating the
accumulated error. Valid on rising edge.
/
*
Read-only parameter
/
*
Read-only parameter
How many pulses are 1cm, please calculate
/
according to the actual mechanical reduction ratio
cm
*
只读参数 Read-only parameter
cm
If it is greater than 32768, it represents a negative
position, with zero as the reference, the upward
cm
position is the positive position, the downward
cm
direction is the negative position, and the position is
cm
- (65535-H1.08)
Calculate the maximum mechanical speed based
cm/s
on the actual mechanical reduction ratio.
Calculate forward deceleration based on maximum
cm/s2
mechanical speed and forward deceleration time
Calculate the reverse deceleration based on the
cm/s2
maximum mechanical speed and the reverse
deceleration time
If the position is normal, the display is 1; otherwise,
/
*
it is displayed as 0.
0: EX-DT01 expansion card is not used, PG card
/
can be used at this time
1: EX-DT01 expansion card is used, PG card is not
Function code selection
27