Function
code
Function code name
number
AI1 ~ AI3, DI analog curve
P6.00
correction
P6.01
Curve 1 input point A0
Reference frequency f0
P6.02
corresponding to curve1
input point A0
P6.03
Curve 1 input point A1
Reference frequency f1
P6.04
corresponding to curve1
input point A1
P6.05
Curve2 input point A0
Reference frequency f0
P6.06
corresponding to curve2
input point A0
P6.07
Curve2 input point A1
high performance crane special inverter User Manual
Factory
Setting range
setting
Group P6
Analog Reference Parameters
4444
0000~4444
0.0
0.0~110.0
0.00
0.00~300.00
100.0
0.0~110.0
50.00
0.00~300.00
0.0
0.0~110.0
0.00
0.00~300.00
100.0
0.0~110.0
Chapter 4 Crane special inverter parameters lists
Unit Property
18: Acceleration and deceleration is prohibited,
If this terminal function is enabled, the current
frequency output will be maintain except stop
command.
19: External fault input,When this terminal is ON,
inverter will stop running and display "E.oUt" fault.
20: Fault reset
21: external interrupt contact input, the output
frequency will be 0 immediately after this function is
effective, and the signal will be automatically
accelerated from 0 to the set frequency after
cancellation
22: Run is prohibited,Once this terminal function is
enable, the motor will coast to stop immediately.
The inverter is allowed to start only when this
terminal function is disabled.
23: The terminal is stopped. When this function is
valid, it will stop immediately according to the stop
mode.
24: Free stop at the terminal, this function is valid,
immediately free parking
25: Stop via terminal with DC braking 1
32: Brake release confirmation
33: Location synchronization
34: Forced location sync is invalid
35: The frequency is switched to P0.13. Once
closed, the frequency is switched to P0.13.
36: The frequency is switched to P0.05. Once
closed, the frequency is switched to P0.05.
37: Forward allows 1, if the forward run is
disconnected, then decelerate to stop
38: Reverse allows 1, if the reverse run is
disconnected, then decelerate to stop
39: Run permission 1, if the running state is
disconnected, decelerate to stop
40: Forward allows 2, if the forward rotation is
disconnected, free parking
41: Reverse allows 2, if the reverse run is
disconnected, free parking
42: Run permission 2, if the operation is
disconnected, free parking
Ones place: AI1 analog curve correction
/
0: Determine the reference frequency
%
according to curve 1 (P6.01 to P6.04)
1: Determine the reference frequency
Hz
according to curve 2 (P6.05 to P6.08)
2: Determine the per unit value determined
%
according to curve 3 (P6.09 to P6.12)
3: Determine the per unit value determined
according to curve 4(P6.13 to P6.30)
Hz
4: Withput curve correction
Tens place: AI2 analog curve correction
%
Same with above
Hundreds place: AI3 analog curve correction
Hz
Same with above
Thousands place: DI analog curve correction
%
Function code selection
19