V&T V5 Series User Manual page 33

Table of Contents

Advertisement

Function
code
Function code name
number
PA.07
Energy saving coefficient
Magnetic flux braking
PA.08
selection
PA.09
Dynamic braking selection
PA.10
Brake unit action hysteresis
PA.11
Braking unit action voltage
Relay action when the
PA.12
inverter is fault
Inverter or motor overload
PA.13
prealarm
Overload pre−alarm
PA.14
detection level
Overload pre−alarm
PA.15
detection time
Fault shielded and alarm
PA.16
attribute setting 1
Fault shielded and alarm
PA.17
attribute setting 2
Fault shielded and alarm
PA.18
attribute setting 3
Fault shielded and alarm
PA.19
attribute setting 4
high performance crane special inverter User Manual
Factory
Setting range
setting
0
0~50
1
0~1
1
0~1
000
000~100
720
650~750
100
000~111
000
000~111
130.0
20.0~200.0
5.0
0.1~60.0
0020
0000~2222
0000
0000~2222
2000
0000~2222
0002
0000~2222
Chapter 4 Crane special inverter parameters lists
Unit Property
0: Disabled
Tens place: Under voltage regulation
0: Disabled
Hundreds place: Over modulation
0: Disabled
%
0~50%
/
×
0: Disabled
/
×
0: Disabled
V
V
Ones place: Under voltage fault
0: Disabled
Tens place: Auto reset interval
/
0: Disabled
Hundreds place: Fault locking
0: Disabled
Ones place: Detected value selection:
0: Motor overload pre−alarm, relative to motor
rated current
1: Inverter overload pre−alarm, relative to inverter
rated current
/
Tens place: Action after overload pre−alarm:
0: Continue running
1: Report overload fault and stop
Hundreds place: Detecting condition selection
0: Detect all the time
1: Only detect at constant speed
%
20.0~200.0%
s
0.1~60.0s
Ones place: Output−ground short
circuit
Tens place: Power failure during
running
/
Hundreds place: Input power
error
Thousands place: Output phase
failure
Ones place: EEPROM error
Tens place: Relay contact
open/close failure
/
Hundreds place: Sensor taking
sample anomaly
Thousands place: Encoder
disconnection
Ones place: +10V output error
Tens place: Analog input error
Hundreds place: Motor over
/
temperature (PTC)
Thousands place:
Communication fault 1 (operation
panel 485)
Ones place: Communication fault
/
2(terminal 485)
Function code selection
1: Enabled
1: Enabled
1: Enabled
1: Enabled
1: Enabled
1: Enabled
1: Enabled
1: Enabled
0: The fault is not
blocked, and the
fault is stopped;
1: The fault is not
blocked, and the
alarm does not
stop;
2: The fault has
been blocked, no
alarm and no
downtime