Function
code
Function code name
number
Running direction
P0.07
command
P0.11
Maximum output frequency
P0.12
Maximum output voltage
P0.13
Frequency high limit
P0.14
Frequency low limit
Basic operating
P0.15
frequency
P1.00
Forward acceleration time
P1.01
Forward deceleration time
P1.02
Reverse Acceleration time
P1.03
Reverse Deceleration time
S-curve acceleration and
P1.04
deceleration time
P1.05
Positive torque increase
P1.06
Reverse torque increase
P1.07
Low speed compensation
P1.08
High speed compensation
Speed compensation
P1.09
switching frequency
Key-lock function
P2.00
selection
P2.01
Multi−function key definition
Display parameter
P2.02
selection at running
16
high performance crane special inverter User Manual
Factory
Setting range
setting
0
50.00
0.01~300.00
380
50.00
0.00~300.00
0.00
0.00~300.00
50.00
0.00~300.00
Group P1 Acceleration and deceleration parameters and torque parameters
8.0
0.0~3600.0
8.0
0.0~3600.0
8.0
0.0~3600.0
8.0
0.0~3600.0
0.0
0.0~6553.5
4.0
0.0~30.0
3.0
0.0~30.0
100.0
0.0~1000.0
100.0
0.0~1000.0
10.00
0.00~300.00
Group P2
0
1
1CB0
0~FFFF
Chapter 4 Crane special inverter parameters lists
Unit Property
0~1
/
Hz
×
1~480
V
×
Hz
×
Hz
×
Hz
×
s
s
s
s
s
%
%
%
%
Hz
Key and Display Parameters
0~3
/
0~8
/
/
Function code selection
0: Run forward
1: Run reverse
The rated voltage of the motor
Lower frequency limit P0.14 ~ Maximum output
frequency P0.11
The rated frequency of the motor
Acceleration time: the time required to accelerate
from 0 to P0.11
Deceleration time: the time required to decelerate
from P0.11 to 0 speed
If the multi-step acceleration/deceleration time is
valid, the multi-stage acceleration/deceleration time
is taken as the actual acceleration/deceleration
time.
Please
refer
to
P4.09~P4.14.
Increase the output voltage and torque when the
inverter runs at low frequency. The magnitude of
the boost should be properly set according to the
load conditions, and the lift is too much, and a large
current surge will occur during the start-up process.
This function is applicable under vector control 1.。
This function helps the inverter to keep the motor
speed stable under load fluctuations and heavy
loads. This function is valid in vector 1 control
mode.
0: No locking;
1: Locking all keys;
2: Locking all keys except MULTI key;
3: Locking all keys except RUN and STOP/RST
keys
0~20: No function
3: Emergency stop 2 (Coast to stop)
4: Switch running command reference
mode(Operation panel / terminal / host computer)
5~8: Reserved
LED ones place:
0: Reference frequency (Hz);1: Bus voltage (V);
2: AI1(V); 3: AI2(V); 4: AI3(V);
5~6: Reserved
7: Motor rotation speed (rpm); 8~9: saved
A: Reference torque (%);
B: Running frequency (Hz);
C: Output current (A);
D: Output torque (%);