V&T V5 Series User Manual page 31

Table of Contents

Advertisement

Function
code
Function code name
number
function selection
AO1 terminal output
P7.03
function selection
AO2 terminal output
P7.04
function selection
P7.05
AO1 gain
P7.06
AOAO1 bias
P7.07
AO2 gain
P7.08
AO2 bias
P7.20
FDT1 level high limit
P7.21
FDT1 level low limit
P7.22
FDT2 level high limit
P7.23
FDT2 level low limit
Terminal effiective status
P7.25
selection
P8.00
Overspeed detection level
Overspeed detection delay
P8.01
P8.02
Stall detection level
Stall detection delay
P8.03
high performance crane special inverter User Manual
Factory
Setting range
setting
48
48~71
49
48~71
100.0
0.0~200.0
0.0
0.0~200.0
100.0
0.0~200.0
0.0
0.0~200.0
3.00
0.00~300.00
2.90
0.00~300.00
3.50
0.00~300.00
3.40
0.00~300.00
0000
0000~1131
Group P8
110.0
0.0~200.0
0.200
0.000~60.000
8.00
0.00~300.00
0.200
0.000~60.000
Chapter 4 Crane special inverter parameters lists
Unit Property
5: Stop and lock due to under voltage (LU)
6: Stop due to external failure (EXT)
7: Frequency high limit(FHL)
8: Frequency low limit(FLL)
9: Inverter is running at zero speed
10~12: reserved
13:Inverter ready completed
14: Inverter failure
19: Output X1
22: Zero current detection arrival (relative to motor)
23: Stop command indication
32: Brake control 33~47: reserved
/
48:Output operating frequency
49:Output setting frequency
/
50:Output current
52:Output torque
%
54:Bus voltage
%
56:AI2
%
58:DI
%
Hz
FDT function can be used for less demanding
brake control, such as truck, car and other
Hz
translation mechanism
Hz
FDT function can be used for less demanding
Hz
brake control, such as truck, car and other
translation mechanism
Ones place: Multi function input terminal Xi:
0: If Xi have current flowing, Xi is enabled
1: If Xi without current flowing, Xi is enabled
Hundreds place: Relay terminal:
Ten digits: Multi-function output terminal Yi
0: Y1 current is valid; Y2 current is valid;
1: Y1 has no current effective; Y2 current is valid;
/
2: Y1 current is valid; Y2 has no current effective;
3: Y1 has no current effective; Y2 has no current
effective;
Hundreds place: relay output terminal
0: If relay enabled, relay is in magnetizing status
1: If relay enabled, relay is not in magnetizing
status
Thousands place: reserved
monitoring parameters
P8.00 is the percentage of the relative maximum
%
frequency P0.11. If the actual speed exceeds the
overspeed detection level and continues for the
s
time set by P8.01, the inverter reports an
overspeed fault.
If the deviation between the actual speed and the
Hz
given speed is greater than the stall detection level
and continues for the time set by P8.03, the inverter
s
reports a stall failure.
Function code selection
15: Inverter reports alarm
20: Output X2
51:Output motor current
53:Output voltage
55:AI1
57:AI3
59:Output power
21

Advertisement

Table of Contents
loading

Related Products for V&T V5 Series

Table of Contents