Function
code
Function code name
number
Fault locking function
PA.20
selection
PA.21
Automatic reset times
PA.22
Automatic reset interval
Hopping frequency 1 low
Pb.00
limit
Hopping frequency 1 high
Pb.01
limit
Hopping frequency 2 low
Pb.02
limit
Hopping frequency 2 high
Pb.03
limit
Hopping frequency 3 low
Pb.04
limit
Hopping frequency 3 high
Pb.05
limit
Restart automatically after
Pb.15
power resumes narmal
Pb.16
Waiting time for restar
Pb.23
Parameter copy
PC.00
Communication baud rate
PC.01
Data format
PC.02
Local address
Communication parameters
PC.03
setting
Pd.00
Speed/torque control
Speed loop proportional
Pd.01
gain 1
(ASR_P1)
Speed loop integral time 1
Pd.02
(ASR_I1)
24
high performance crane special inverter User Manual
Factory
Setting range
setting
0
0~1
0
0~20
2.0
2.0~20.0
Group Pb
Enhanced Function Parameters
0.00
0.00~300.00
0.00
0.00~300.00
0.00
0.00~300.00
0.00
0.00~300.00
0.00
0.00~300.00
0.00
0.00~300.00
0
0~1
0.5
0.0~20.0
0
0~5
Group PC
Communication Parameters
6
4~8
0
0~2
1
1~247
303
000~F0F
Group Pd
Vector Control 2 Parameters
00
00~21
2.00
0.000~30.00
0.200
0.000~6.000
Chapter 4 Crane special inverter parameters lists
Unit Property
Tens place: Version incompatible
Hundreds place: Reserve
Thousands place: Reserve
0: Fault is not locked
/
1: Fault is locked
/
0~20
s
2.0~20.0s
Setting range: P0.13~P0.14
Hz
×
Set hopping frequency range of inverter to avoid
mechanical resonance. When the setting frequency
Hz
×
of inverter is less than the hopping frequency, the
inverter will run automatically at the high limit or low
limit of the hopping frequency (change to run at low
Hz
×
limit of the hopping frequency when acceleration,
for deceleration, change to run at high limit of the
Hz
×
hopping frequency)
Hz
×
Hz
×
0: Disabled
/
×
1: Enabled
s
0.0~20.0s
0: No function
1: Parameter upload
2: Parameter download (without motor parameters)
/
×
3: Parameter download (with motor parameters)
4: Parameter upload is prohibited
5: Parameter upload is allowed
4:4800 bps;
bps
7:38400 bps;
0: 1−8−1 format, no parity
/
1: 1−8−1 format, odd parity
2: 1−8−1 format, even parity
/
1 ~ 247, 0 is broadcasting address
303: communication write RAM
F0F: communication write EEPROM
/
Note: To avoid bad communication write EEPROM,
please keep the default value
Ones place: Speed control/torque control selection:
0: Speed control
1: Torque control
/
Tens place:Torque direction under torque control:
0: Determine by analog input
1: Consistent with the running direction
2: Inconsistent with the running direction
/
s
Function code selection
5:9600 bps; 6:19200 bps;
8:57600 bps;