Raycus pulsed fiber laser is classified as a high power Class IV laser device. Before supplying the power to the device, please make sure that the correct voltage of 24V DC power source is connected and the anode and cathode are right.
Caution: Make sure the corresponding wires of the device are properly grounded. b) All the maintenance to the device should only be done by Raycus, because there is no replacement or accessory provided with the device. Please do not try to damage the labels or open the cover in order to prevent against electric shock, or the warranty will be invalid.
Wuhan Raycus Fiber Laser Technologies CO., Ltd. Pulsed Fiber Laser User’s Guide V2.1 P20QB/P30QB e) Do not install the collimating device into the output head when the laser device is in working f) The device has three cooling fans at the rear panel to dissipate heat. In order to guarantee enough airflow to help giving heat off, there must be a space of at least 10cm’s width for airflow in front and rear side of the device.
Wuhan Raycus Fiber Laser Technologies CO., Ltd. Pulsed Fiber Laser User’s Guide V2.1 P20QB/P30QB 2. Mounting Mounting dimensions a) Fiber Laser module dimensions (As shown in Fig. 1). Figure 1. Dimension drawing of laser module (Unit: mm). b) Isolated output isolator (As shown in Fig. 2).
Page 8
Wuhan Raycus Fiber Laser Technologies CO., Ltd. Pulsed Fiber Laser User’s Guide V2.1 P20QB/P30QB damaging due to vibration during the transportation. b) Fix the laser device steady on the holder and ensure good ventilation. c) The power connector of this high performance small volume laser device is DB7 dual power supply.
Wuhan Raycus Fiber Laser Technologies CO., Ltd. Pulsed Fiber Laser User’s Guide V2.1 P20QB/P30QB 3. Control Interface There are DB9 and DB25 interfaces at the rear of the laser. The DB9 is a RS232 interface only used for debugging, no needs to connect. And DB25 is the joint interface connecting control system to the laser system, please make sure the connection is reliable before operation.
Wuhan Raycus Fiber Laser Technologies CO., Ltd. Pulsed Fiber Laser User’s Guide V2.1 P20QB/P30QB signal must be switched ON, in other word, the signal of PIN 18 must be ahead of PIN 19 at least 5 ms, and otherwise the laser machine may be damaged.
Raycus has the right to choose to repair or replace any product that proves to be defective in materials and workmanship selectively during the warranty period. Only products with particular defects are under warranty.
Page 13
If any damage happens to the product, please notify the carrier in document immediately. All the items about warranty and service above provided by Raycus are only for reference; formal contents about warranty and service are subject to the contract.