Configuring Exposure And External Trigger Settings - JAI SP-12000M-CXP4-XT User Manual

12m digital progressive scan monochrome and color camera
Table of Contents

Advertisement

Example: When changing [Pixel Format]
Note
Direct entry of numerical and text values is possible for some setting items.

Configuring Exposure and External Trigger Settings

Configure settings related to exposure control methods and trigger control.
The factory default settings are as follows. Change settings as necessary, according to the intended
purpose or application.
Factory default values
Trigger Selector (trigger operation)
Trigger Mode
Trigger Source (trigger signal source)
Trigger Activation (trigger polarity)
Trigger Overlap
Trigger Option
Exposure Mode
Exposure Time
Exposure Auto*
* This item is only enabled when [Exposure Mode] is set to [Timed].
Caution
When [Exposure Mode] is set to [Off], [Trigger Mode] cannot be set to [On]. Other settings may also be restricted
depending on the exposure mode, so be sure to set the exposure mode before configuring the trigger settings.
Configure the settings by expanding [Acquisition Control] and configuring the following items.
Caution
Settings can only be configured when image acquisition on the camera is stopped. If an item is grayed
out and the setting cannot be changed, stop image acquisition beforehand.
Item
— 18 —
Default value
Frame Start
Off
Line 4 - TTL In 1
Rising Edge (rising edge of input signal)
Read Out
Off
Timed (control via exposure time)
10486 (μs)
Off
SP-12000M-CXP4 / SP-12000C-CXP4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-12000c-cxp4-xtSp-12000m-cxp4-f