Troubleshooting The Temperature Probe; Replacing The Transformer, Reset Switch Or Filter Relay - Frymaster OCF30ATOG Service & Parts Manual

Oil conserving fryer gas fryers
Table of Contents

Advertisement

If 24 VAC is present across gas valve main coil, check the incoming gas pressure and compare to the
tables on page 2-4 of the Installation and Operation manual.
1. If incoming gas pressure is not correct, the probable cause is a problem with the gas supply to fryer.
2. If incoming gas pressure is correct, check the burner manifold gas pressure and compare it to the
tables on page 2-7 of the Installation and Operation manual.
a. If burner manifold gas pressure is not correct, the probable cause is an improperly adjusted or
failed gas valve. Adjust the valve by following the procedure "Check Burner Manifold Pressure"
in Section 1.7 of this manual. If the valve cannot be adjusted, replace it.
b. If outgoing gas pressure is correct, the gas valve is okay.

1.11.3 Troubleshooting the Temperature Probe

Disconnect the 3000 controller before testing temperature probe resistances to avoid
invalid readings
Prior to checking for problems associated with the temperature probe, inspect the probe body for damage
while it is still in the frypot. Remove and replace the probe if it is bent, dented, or cracked. Also, inspect leads
for fraying, burning, breaks, and/or kinks. If found, replace the probe.
The following processes will assist you in troubleshooting the temperature probe and ruling it out as a
probable cause:
Before testing the probe, determine the temperature of the cooking oil using another thermometer or
pyrometer placed at the tip of the questionable probe.
If resistance through J3 pins 2 and 6 (J1 pins 2 and 6 for left side of dual unit) is not approximately
equal to that given in the Probe Resistance Chart for the corresponding temperature, the probe has
failed and must be replaced.
If resistance through J3 pins 2 and 6 (J1 pins 2 and 6 for left side of dual unit) is approximately
equal to that given in the Probe Resistance Chart for the corresponding temperature, measure the
resistance through each of the previously tested pins to ground.
1. If resistance is not 5 mega-Ohms or greater in each pin, the probe has failed and must be replaced.
2. If resistance is 5 mega-Ohms or greater in each pin, the probe is okay.

1.11.4 Replacing the Transformer, Reset Switch or Filter Relay

Disconnect the fryer from the electrical power supply. Remove the cover from the transformer box in the rear
of the fryer to expose the interior of the transformer box. Replace the transformer or filter relay marking the
wires to ease reassembly.
transformer, ensure the 24VAC relay (8070012) is used.
CAUTION
Once replaced, reconnect the power. When replacing a filter relay in the
1-26