Quicksilver 905WE — System & Component Overview and Operation
vent located on the port side above the interior closet. In the aft berth, there is a vent located on the
port side of the headliner, while in the salon, there is a vent located on the port aft pilaster.
Single Air Conditioning Unit
Dual Air Conditioning Units
The reverse cycle air conditioning system consists of a 8,000 BTU and 16,000 BTU self contained air
conditioning units, a seawater pickup, strainer, water pump, and control panel. The 16,000 BTU air
conditioning unit is located on the port side of the salon, can be easily accessed by removing a panel
located in the aft salon bench seat. The 8,000 BTU unit is located in the forward berth storage under
the bed. Care should be taken to not stow items around the unit that may block the return air grill or
damage the refrigerant gas lines to the compressor.
Dual Unit Operation
Prior to starting the air conditioner make sure that the water pickup seacock, located in the port side
of the bilge and accessed through the forward cockpit floor hatch, is OPENED. The 16,000 BTU air
conditioner is controlled by a keypad located on the port side of the salon provides air to the aft berth
and salon. The 8,000 BTU unit provides air to the forward berth only. The second control panel is
located on the starboard side of the forward berth. Each panel allows for either automatic control of a
preset temperature, or it allows you to vary the blower speed and temperature manually. When the
air conditioner unit is turned on, seawater is pumped into the system through the seacock and
strainer. The water passes through the compressor cooling the condensing coils, then it flows
overboard to a thru hull drain. Any condensation on the air conditioner unit will collect into a
condensation pan and then drain overboard, either via gravity or a sump pump.
44
Water pickup
Seacock
Sea strainer
Water pump
Air conditioner unit
Water outlet hose
Water outlet thru hull
Condensation hose
Condensation thru hull
Air duct
Aft berth grill
Forward berth grill
Salon grill
Return air vent
Control panel