Advertisement

810 Arvor Owner's Manual

Advertisement

Table of Contents
loading

Summary of Contents for Quicksilver 810 Arvor

  • Page 1 810 Arvor Owner’s Manual...
  • Page 3 Welcome Congratulations on becoming a new owner of a Quicksilver® boat. This Owner’s Packet will provide important information about the features of your boat and should be, at all times, kept aboard your boat. Take time to carefully review the information in this packet to really get to know your boat.
  • Page 4 Information in this publication is based upon the latest production specifications available at printing. Quicksilver® reserves the right to make changes at any time, without notice, in the colors, equipment, specifications, materials and prices of all models, or to discontinue models. Should changes in production models be made, Quicksilver®...
  • Page 5: Table Of Contents

    Table of Contents Introduction 11. Bow Thruster ..........24 1. Owner’s Manual .......... vi 12. Steering ............26 2. Your Responsibilities ........vi 13. Engine Operation ........27 3. Safety / Warning Labels ....... vi 14. Engine Controls .......... 28 4.
  • Page 6: Introduction

    Introduction 1. Owner’s Manual The material here and the rest of the Owner’s manual packet:  Gives you basic safety information  Describes the fundamentals of boat use  Describes the features of your boat  Describes the equipment on your boat ...
  • Page 7: Dealer Responsibilities

    The CIN consists of a two digit country code indicating the country of origin of the manufacturer and a unique twelve digit code that provides Quicksilver® vital information about your boat. The CIN must be included in all correspondence related to the vessel.
  • Page 8 This Limited Warranty does not apply to any Quicksilver® which has been salvaged or declared a total loss or a constructive total loss for any reasons not covered in this Limited Warranty. This Limited Warranty also does not apply to the following items: 1.
  • Page 9 Limited Warranties stated. To the extent allowed by law neither Brunswick Marine in EMEA, not the selling dealer shall have any responsibility of the loss of use of the Quicksilver®, loss of time, inconvenience, commercial loss or consequential damages.
  • Page 10 Limited Warranty, and the owner must notify Brunswick Marine in EMEA of any Quicksilver® being repaired by an authorized Brunswick Marine in EMEA dealer which has been at the dealership for fifteen (15) days, or of any claimed defect which was not corrected after one (1) repair attempt.
  • Page 11 Limited Warranties stated. To the extent allowed by law neither Brunswick Marine in EMEA, not the selling dealer shall have any responsibility of the loss of use of the Quicksilver®, loss of...
  • Page 12 Limited Warranty, and the owner must notify Brunswick Marine in EMEA of any Quicksilver® being repaired by an authorized Brunswick Marine in EMEA dealer which has been at the dealership for fifteen (15) days, or of any claimed defect which was not corrected after one (1) repair attempt.
  • Page 13: Basic Boat Dimensions & Specifications

    Quicksilver 810 Arvor — General Information 1. Basic Boat Dimensions & Specifications Manufacturer: Brunswick Marine in EMEA Model: Quicksilver Arvor 810 Design Category: Length of Hull (L 7.19m Light Craft Mass (m 2873kg Length Overall (L 8.30m Maximum Load (m...
  • Page 14: Vessel Stability

    Quicksilver 810 Arvor — General Information 2. Vessel Stability The following maximum load has been used for assessing the stability and buoyancy comprising  Manufacturer’s maximum recommended load per ISO 14946 715kg  Fuel, fresh water, other fluids to maximum capacity of fixed tanks...
  • Page 15: Passenger Locations

    Quicksilver 810 Arvor — General Information 4. Passenger Locations Be aware of your footing while the boat is underway. Gelcoat surfaces are slippery when wet. Use extreme Slipping or falling could result in serious injury or death, caution when walking on wet surfaces.
  • Page 16: Safety Label Locations

    Quicksilver 810 Arvor — General Information 6. Safety Label Locations...
  • Page 17 Quicksilver 810 Arvor — General Information Safety Label Locations...
  • Page 18: Deck/Cockpit Layout

    Quicksilver 810 Arvor — General Information 7. Deck / Cockpit Layout Anchor roller Bow windlass Bow cleat (P&S) Bow rail (P&S) Hardtop Navigation lights (P&S) Hardtop rail (P&S) Sliding window (P&S) Midship cleat (P&S) Water deck plate Waste pumpout Rod holder (P&S) Coaming cap (P&S)
  • Page 19: Cockpit Storage

    Aft cockpit storage Starboard cockpit storage Do not store any equipment containing petrol (outboard Quicksilver® recommends that the liferaft store in the aft engines, portable petrol tanks, etc.) in any interior storage cockpit hatch area. areas. These compartments were not designed to store...
  • Page 20: Thru Hull Locations

    Quicksilver 810 Arvor — General Information 9. Thru Hull Locations Starboard cockpit drain Water tank vent Engine exhaust Toilet water pickup Livewell drain Waste tank vent Engine air box drain Engine cooling water pickup Diesel heat exhaust Bilge pump drain...
  • Page 21: Dash Layout

    Quicksilver 810 Arvor — General Information 10. Dash Layout SmartCraft gauges Stereo 12V outlet USB receptacle Helm switches Steering wheel Bow thruster control Trim tab switches Fire extinguisher override Windlass switch Trolling valve control Engine throttle shift control Please note that operator vision from the helm may be obstructed by high trim angles of the craft, along with other factors such as hull trim plane angles, loading and load distribution, speed &...
  • Page 22: Engine

    The maximum power rating label is located at the helm, under the capacity plate. Quicksilver® recommends that you fully comply with the manual provided by the engine manufacturer. Follow the recommended maintenance and warranty schedule in your Engine Operator’s Manual.
  • Page 23: Fuel System

    Quicksilver 810 Arvor — System & Component Overview and Operation 1. Fuel System Your boat’s diesel fuel system consists of a fuel tank, a fuel tank fill and vent fitting, a sending unit, a shutoff valve, an engine fuel supply line, and an engine fuel return line. In addition, there is an inline fuel filter to provide the adequate level of filtration for the system.
  • Page 24: Water System

    Quicksilver 810 Arvor — System & Component Overview and Operation removed and the tank completely dried before refilling the tank with any fuel. Check the fuel lines frequently for leaks or any surface cracking on the hose. Replace the hose immediately if any issues are found.
  • Page 25: Black Water System (Optional)

    Quicksilver 810 Arvor — System & Component Overview and Operation Fresh Water System Water tank fill Water pump strainer Water tank vent Water pump Water tank vent hose Galley faucet hose Water tank fill hose Galley faucet Water tank Water tank to water pump hose 3.
  • Page 26 Quicksilver 810 Arvor — System & Component Overview and Operation Black Water System Toilet water pickup Overboard discharge Pickup to toilet water hose Holding tank to pumpout hose Toilet Pumpout deck plate Toilet to holding tank hose Holding tank to vent filter hose...
  • Page 27: Bilge Pumps

    (i.e. cleaning materials, safe deodorants to use for the system), contact your local dealer. Quicksilver® recommends that you pump out the system before long periods of non-use. If you are storing the boat during the winter, we recommend you winterize the system.
  • Page 28: Livewell & Raw Water Washdown

    Quicksilver 810 Arvor — System & Component Overview and Operation Typical Bilge Pump System Bilge pump Bilge pump hose Thru hull 5. Livewell & Raw Water Washdown This boat comes installed with a 75 liter livewell and raw water washdown system. The livewell is located in the aft cockpit, while the raw water washdown is located at the starboard aft corner of the cockpit.
  • Page 29: Fire Suppression

    Quicksilver 810 Arvor — System & Component Overview and Operation Livewell—Raw water Livewell/ raw water pickup valve Livewell pump Raw water pump Livewell tub Livewell drain tube Livewell drain thru hull In-line water filter Raw water sprayer hose Vented loop...
  • Page 30: Carbon Monoxide Monitor

    Fire extinguisher 7. Carbon Monoxide Monitor Quicksilver® boats are equipped with carbon monoxide (CO) monitors in the cabin and enclosed berths or staterooms. Carbon Monoxide is an odorless, colorless, tasteless, and extremely toxic gas produced by engines, heaters, stoves or generators. When inhaled it combines with hemoglobin in the blood, preventing absorption of oxygen and is unlikely to be noticed until the person is overcome.
  • Page 31 Quicksilver 810 Arvor — System & Component Overview and Operation Carbon Monoxide Accumulation & Prevention Carbon Monoxide can accumulate in dangerous concentrations anywhere in or around your boat including on back decks, swim platforms, or in water around generator exhausts. CO can remain in or around your boat at dangerous levels even if your engine is no longer running.
  • Page 32: Lpg System

    Your boat’s LPG system consists of a stove, a shutoff valve, and a storage tub for two 2kg LPG tanks. Quicksilver® does not provide a tank or a regulator with the boat, however, both can be purchased through your authorized Quicksilver® dealer.
  • Page 33 Quicksilver 810 Arvor — System & Component Overview and Operation Tank Storage The LPG tank storage is located in the starboard walkthrough. The tanks must be firmly secured to the boat with the tanks in a horizontal position. Do not relocate or reposition the tanks. Do not obstruct access to the LPG tanks in any way.
  • Page 34: Bow Anchor Windlass

    System Leak Test Prior to the boat leaving the factory, the LPG system is tested for any potential leaks. However, Quicksilver® recommends that you test the system regularly. Test all connections for leakage by means of the following: 1. Before each use, close appliance valves; open LPG cylinder valve; allow indicated gauge pressure to stabilize;...
  • Page 35 In the event that there is a loss of power, the windlass can still be used to raise or lower the anchor manually. If there is a loss of power, check the windlass breaker to see if it needs to be reset. If you reset the breaker and it continues to trip, have your authorized Quicksilver® dealer inspect the system.
  • Page 36: Stern Anchor Windlass (Optional)

    Quicksilver 810 Arvor — System & Component Overview and Operation 10. Stern Anchor Windlass (optional) The anchor windlass located at the stern of the boat assists with the anchoring of your boat by automatically raising and lowering the anchor. The windlass is operated from the helm or by a handheld remote control key FOB.
  • Page 37 Quicksilver 810 Arvor — System & Component Overview and Operation continuously. Press the on/off switch again within 6 seconds . The system will confirm that it is ready for use when the LED light remains green and the buzzer sounds twice.
  • Page 38: Steering

    Quicksilver 810 Arvor — System & Component Overview and Operation 12. Steering Your boat comes equipped with a hydraulic steering system connected to a single rudder. The basic system for a single engine boat contains a steering wheel, a hydraulic helm pump, a hydraulic steering cylinder, hydraulic hoses, and a bypass valve system.
  • Page 39: Engine Operation

    Quicksilver 810 Arvor — System & Component Overview and Operation 13. Engine Operation Your boat is powered by a Mercury 2.8L closed cooled diesel engine with a transmission connected to a straight drive shaft. Prior to operation of the vessel, the following will need to be observed: Engine Cooling System Make sure that engine cooling water is flowing throughout the system.
  • Page 40: Engine Controls

    Quicksilver 810 Arvor — System & Component Overview and Operation Exhaust System Your boat is equipped with a thru hull exhaust system with an inline muffler located on the starboard side of the boat. Water from the cooling system enters the exhaust system through the engine exhaust manifold, where water and exhaust are mixed.
  • Page 41: Tm Gauges

    Quicksilver 810 Arvor — System & Component Overview and Operation The lanyard should be long enough to prevent inadvertent activation. Do not let the lanyard become entangled. Engine Controls “Throttle Only” button Shut down switch Vernier trolling control Maximum engine speed in troll mode is 1200 RPM.
  • Page 42 Quicksilver 810 Arvor — System & Component Overview and Operation Helm Control Transfer To switch control from the main helm to the exterior helm, pull out and rotate the handle clockwise 90 degrees until it locks into position. You will now have control of the engine at the exterior helm. To return control back to the main helm, pull out and rotate the handle counter-clockwise 90 degrees until it locks into position.
  • Page 43: Diesel Heat (Optional)

    Quicksilver 810 Arvor — System & Component Overview and Operation Vision from the exterior helm station is limited. Maintain a DO NOT TURN THE STEERING WHEEL AT THE HELM lookout as required. Do not operate at planing speeds from THAT DOES NOT HAVE FULL CONTROL OF THE BOAT.
  • Page 44: Stereo (Optional)

    Quicksilver 810 Arvor — System & Component Overview and Operation Exhaust gas is HOT. Ensure that there is nothing that is susceptible to heat damage (i.e. ropes, fenders, other boats) within 200mm of the exhaust outlet. 20. Stereo (optional) Your boat may come equipped with a Fusion AM/FM stereo with Bluetooth®. The stereo unit along with a USB port, is located at the helm.
  • Page 45: Cockpit Sunshade (Optional)

    Quicksilver 810 Arvor — System & Component Overview and Operation 23. Cockpit Sunshade (optional) If installed, an optional cockpit sunshade is available to provide protection from the sun. The cockpit sunshade consists of a rail on the hardtop and a canvas.
  • Page 46: Dc Electrical

    Quicksilver 810 Arvor— Electrical Systems 1. DC Electrical System The DC electrical system is powered by a single battery, and is kept charged by the engine driven alternator. 2. Battery Refer to your engine owner’s manual for exact battery requirements.
  • Page 47: Fuses And Breakers

    Quicksilver 810 Arvor — Electrical Systems 5. Fuses and Breakers Your boat will either have fuses or breakers protecting the DC electrical system. If you have to replace a fuse or electrical breaker, replace only with a fuse or breaker of the same rating. The amperage will be marked on the fuse or breaker, and it is recommended that you carry spare fuses or breakers.
  • Page 48: Ac System (Optional)

    A shore power cable is not included, however, your authorized Quicksilver® dealer will be able to provide you one along with the correct plug (for use in your region) for the other end of the shore power cable.
  • Page 49: Galvanic Isolator

    Quicksilver 810 Arvor — Electrical Systems Turning Off and Disconnecting Shore Power To disconnect shore power: On the Boat 1. Make sure that the all of the breakers on the AC Distribution Panel are OFF On the Dock 1. Turn OFF the dock breaker.
  • Page 50: Electrical Schematics

    These electrical schematics were generated by the Electrical Engineering Department for technical reference and service technicians. Quicksilver® does not recommend that you attempt to work on the boat’s electrical system yourself. Instead, we recommend that you take your boat to your local authorized Quicksilver®...
  • Page 51 Quicksilver 810 Arvor — Electrical Systems DC Wiring Schematic...
  • Page 52 Quicksilver 810 Arvor— Electrical Systems 230V AC Schematic Stern Windlass Schematic...
  • Page 53: Maintenance

    If the growth is more severe, you may need to enlist the services of a professional hull cleaning company. Check with your Quicksilver® dealer for recommendations on a compatible rubbing compound for your boat or a professional hull cleaning company in your area.
  • Page 54: Component Maintenance

    Frequent routine cleaning of your stainless steel will help maintain the finish. Quicksilver® recommends that you wash stainless steel components with mild soap and cold or lukewarm water after every use of the boat. If added protection is necessary, apply a cleaning wax.
  • Page 55 Do not store any of the canvas pieces while wet. The effects of ultraviolet light can sometimes be reduced by chemical treatment of canvas items. Consult your Quicksilver® dealer or check your canvas manufacturer’s manual before using any chemical treatments on your canvas.
  • Page 56: Engine Shaft Alignment

    Quicksilver 810 Arvor — Maintenance Dry the window with a soft cloth or chamois to prevent water spots. Polish with a separate cloth. Don’t leave cleaners on for long periods; immediately wash the window. Finally, don’t apply cleaners in direct sunlight or at elevated temperatures.

Table of Contents