4.0 System Diagnostics and Eco Features

7
Manual Test will detect open circuits (less than 30 mA draw) on
any used zone or a short on any output (master valve or zone). If
the display indicates FAULT while running a Manual Test, refer to
Advanced Menu to identify the FAULT.

3.3 Manual Program

Manual Program allows you to start
any program set up in the controller; A,
B, C or D. Zones will run for the time
set at Zone Run Times for the selected
program.
Turn dial to Manual Program. OFF
will appear in the screen.
Use UP and DOWN arrows to select
the program you want to run (PROG
A, B, C or D)
Return dial to RUN. Program will commence watering. At the
end of the manual watering cycle, the controller will return to
automatic RUN mode.
1 amp = 1,000 milliamps
0.250 A
250 mA
0.500 A
500 mA
0.750 A
750 mA
1.000 A
1,000 mA
http://support.weathermatic.com
4.0 System Diagnostics and Eco Features
Your ProLine® controller has both System Diagnostic and Eco
Friendly dial positions:

4.1 Multimeter

Outputs
Turn dial to Multimeter position.
RUN
RUN
Outputs will appear on the screen. Push
M A N UA L ZO N E
M A N UA L ZO N E
SYST E M O F F
SYST E M O F F
the NEXT button to check the amperage
M A N UA L T E ST
M A N UA L T E ST
C U R R E N T T I M E / DAT E
C U R R E N T T I M E / DAT E
M A N UA L P R O G R A M
P R O G R A M STA R T T I ME S
P R O G R A M STA R T T I M E S
output for the MV (master valve) and
M U LT I M E T E R
M U LT I M E T E R
ZO N E R U N T I M E S
ZO N E R U N T I M E S
each numbered zone. Typical range is
VA LV E LO C ATO R
VA LV E LO C ATO R
DAYS TO WAT E R
DAYS TO WAT E R
.150 to .350 Amps. Anything less than
SENSOR OPERATION
SENSOR OPERATION
OMIT TIMES / DAYS
OMIT TIMES / DAYS
.03 Amps is considered an open circuit
RUN AND SOAK CYCLES
RUN AND SOAK CYCLES
SEASONAL % ADJUST
SEASONAL % ADJUST
ADVANCED
ADVANCED
for that zone. If an Open or Short
MENU
MENU
fault message appears during this testing, the fault indication is
identifying the electrical problem (short circuit or open circuit)
with the zone. Note: If you have more than one valve on a zone,
the ProLine® controller will measure total current for the combined
valves.
Battery
To check the battery voltage level (applies to PL1600 & PL4800
only), turn dial to Multimeter. Outputs will appear on the screen.
Push the Adjust Value up arrow button one time. Battery will
appear on the screen. Push the Next button once to read battery
voltage status. A minimum of 7.5V is required to operate the
screen. ProLine® controllers use a Real Time Calendar Clock
instead of a backup battery to maintain correct time during a
power outage. A battery is only necessary for viewing the screen
and programming when the panel is removed from the housing.
RUN
RUN
M A N UA L ZO N E
M A N UA L ZO N E
SYST E M O F F
SYST E M O F F
M A N UA L T E ST
M A N UA L T E ST
C U R R E N T T I M E / DAT E
C U R R E N T T I M E / DAT E
M A N UA L P R O G R A M
M A N UA L P R O G R A M
P R O G R A M STA R T T I M E S
P R O G R A M STA R T T I ME S
M U LT I M E T E R
ZO N E R U N T I M E S
ZO N E R U N T I M E S
VA LV E LO C ATO R
VA LV E LO C ATO R
DAYS TO WAT E R
DAYS TO WAT E R
SENSOR OPERATION
SENSOR OPERATION
OMIT TIMES / DAYS
OMIT TIMES / DAYS
RUN AND SOAK CYCLES
RUN AND SOAK CYCLES
SEASONAL % ADJUST
SEASONAL % ADJUST
ADVANCED
ADVANCED
MENU
MENU

Advertisement

Table of Contents
loading

Table of Contents