24V Power
To check transformer voltage, turn dial to Multimeter. Outputs will
appear in the screen. Press Adjust Value up arrow button until you
get 24V Power. Push Next button once to read output voltage for
the transformer. Normal reading is 24 to 30 volts AC.

4.2 Valve Locator

This patented feature will rapidly cycle power to a solenoid valve
to create a "chatter" for a selected
valve as a convenient method of
locating buried valves. Use NEXT
button to scroll to the valve you want
to "chatter". You will need to turn off
the main water valve for the Valve
Locator feature to work properly.
Note: As many valves are located
underground, the sound may be dampened. If this is the case, you
will need to listen carefully for the valve "chatter".
Note:
In order for the locator feature to work,
you will need to turn off the system water
pressure at the manual cut-off valve or water
meter. Pressure must be off while attempting
to "chatter" a valve. The ProLine® controller will
automatically sequence "chatter" to each valve including
the master valve(s).
4.0 System Diagnostic and Eco Features

4.3 Sensor Operation

Sensor
The Sensor Operation function is
used to omit selected zones from
sensor shutdown during rain or freeze
conditions. Factory default is all zones
included for sensor shutdown. If you
have zones like potted plants under
cover, you may wish to omit those
zones from sensor shutdown. Turn
RUN
RUN
M A N UA L ZO N E
M A N UA L ZO N E
SYST E M O F F
SYST E M O F F
dial to Sensor Operation. Push NEXT
M A N UA L T E ST
M A N UA L T E ST
C U R R E N T T I M E / DAT E
C U R R E N T T I M E / DAT E
button to view SENSOR and NEXT again to view first zone. Use
M A N UA L P R O G R A M
M A N UA L P R O G R A M
P R O G R A M STA R T T I ME S
P R O G R A M STA R T T I M E S
up or down Adjust Value buttons to select sensor ON or OFF
M U LT I M E T E R
M U LT I M E T E R
ZO N E R U N T I M E S
ZO N E R U N T I M E S
for the zone. OFF means the zone WILL WATER during sensor
VA LV E LO C ATO R
DAYS TO WAT E R
DAYS TO WAT E R
shutdown.
SENSOR OPERATION
SENSOR OPERATION
OMIT TIMES / DAYS
OMIT TIMES / DAYS
RUN AND SOAK CYCLES
RUN AND SOAK CYCLES
SEASONAL % ADJUST
SEASONAL % ADJUST
ADVANCED
ADVANCED
RFS
MENU
MENU
ProLine® controllers can utilize the RFS Sensor for Rain and
Freeze Shutdown. This means that you can take advantage of
differentiating between Rain and Freeze events, unlike standard
sensors on the market. Another powerful feature is the ability
to extend a Rain shutdown event beyond the short time the Rain
sensor is actually wet, saving even more water.
Press the NEXT button at SLW to display DELAY. Press NEXT
again to display the number of hours the controller will suspend
irrigation after the Rain sensor has dried out. The factory default
is 48 hours.
RAIN and FREEZE selections work the same as SENSOR described
above, however allow you to differentiate between rain and freeze
events. For example, you may want your potted plants to irrigate
during rain but not during a freeze.
8
RUN
RUN
M A N UA L ZO N E
M A N UA L ZO N E
SYST E M O F F
SYST E M O F F
M A N UA L T E ST
M A N UA L T E ST
C U R R E N T T I M E / DAT E
C U R R E N T T I M E / DAT E
M A N UA L P R O G R A M
M A N UA L P R O G R A M
P R O G R A M STA R T T I ME S
P R O G R A M STA R T T I M E S
M U LT I M E T E R
M U LT I M E T E R
ZO N E R U N T I M E S
ZO N E R U N T I M E S
VA LV E LO C ATO R
VA LV E LO C ATO R
DAYS TO WAT E R
DAYS TO WAT E R
SENSOR OPERATION
OMIT TIMES / DAYS
OMIT TIMES / DAYS
RUN AND SOAK CYCLES
RUN AND SOAK CYCLES
SEASONAL % ADJUST
SEASONAL % ADJUST
ADVANCED
ADVANCED
MENU
MENU
http://support.weathermatic.com

Advertisement

Table of Contents
loading

Table of Contents