Delta Electronics VFD-M Series User Manual page 38

High performance / low-noise micro-type ac motor drives
Table of Contents

Advertisement

Parameter
Explanation
Pr.08
Minimum Output Freq 0.10 to 20.00Hz
Minimum Output
Pr.09
Voltage
Pr.10
Acceleration Time 1
Pr.11
Deceleration Time 1
Pr.12
Acceleration Time 2
Pr.13
Deceleration Time 2
Pr.14
Accel S-curve
Pr.15
Jog Accel/Decel Time 0.1 to 600.0 sec or 0.01 to 600.0 sec
Pr.16
Jog Frequency
Pr.17
1st Step Speed Freq. 0.00 to 400.0Hz
Pr.18
2nd Step Speed Freq. 0.00 to 400.0Hz
Pr.19
3rd Step Speed Freq. 0.00 to 400.0Hz
Pr.20
4th Step Speed Freq. 0.00 to 400.0Hz
Pr.21
5th Step Speed Freq. 0.00 to 400.0Hz
Pr.22
6th Step Speed Freq. 0.00 to 400.0Hz
Pr.23
7th Step Speed Freq. 0.00 to 400.0Hz
Reverse Operation
Pr.24
Inhibition
Over-Voltage Stall
Pr.25
Prevention
Over-current Stall
Pr.26
Prevention during
Acceleration
Over-current Stall
Pr.27
Prevention during
Operation
DC Braking Current
Pr.28
Level
DC Braking during
Pr.29
Start-up
Revision May 2008, ME14, SW V3.04
Settings
115V/230V: 0.1 to 255.0V
460V: 0.1 to 510.0V
575V: 0.1 to 637.0V
0.1 to 600.0 sec or 0.01 to 600.0 sec
0.1 to 600.0 sec or 0.01 to 600.0 sec
0.1 to 600.0 sec or 0.01 to 600.0 sec
0.1 to 600.0 sec or 0.01 to 600.0 sec
00 to 07
0.00 to 400.0 Hz
00: Enable REV operation
01: Disable REV operation
00: Disable
115V/230V: 330 to 450 Vdc
460V: 660 to 900 Vdc
575V: 825 to 1025 Vdc
00: Disable
20% to 200%
00: Disable
20% to 200%
00 to 100 %
0.0 to 5.0 sec
Chapter 4 Parameters|
Factory
Setting
1.50
10.0
20.0
26.1
10.0
10.0
10.0
10.0
00
1.0
6.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
00
390
780
975
150
150
00
0.0
Customer
4-3