Control Terminal Wiring (Factory Settings) - Delta Electronics VFD-M Series User Manual

High performance / low-noise micro-type ac motor drives
Table of Contents

Advertisement

2.4 Control Terminal Wiring (Factory Settings)

Wire Type: 75 C, Copper Only
Wire Gauge: 24-12 AWG
Torque: 4kgf-cm (3.5 in-lbf)
RA RB RC
Relay contactor
Output
Factory Setting
Multi-step speed 1
Multi-step speed 2
Multi-step speed 3
NPN Mode
N PN mo de wi th ou t ext ern al p o we r
Fo rwa rd/St op
R eve rse /Sto p
R ese t
Mu lti -ste p 1
Mu lti -ste p 2
Mu lti -ste p 3
C ommo n Si gn al
NOTE
Don' t a pply the mains voltage
direc tly to above t erminals .
Terminal symbols and functions
Terminal
Symbol
Multi-Function Relay Output
RA
(N.O.) a
Multi-Function Relay Output
RB
(N.C.) b
Revision May 2008, ME14, SW V3.04
M0 M1 M2 M3 M4 M5 GND AFM
Forward/Stop
Reverse/Stop
Reset
+2 4V
M0
M1
M2
M3
M4
M5
GN D
E
Terminal Function
Chapter 2 Installation and Wiring|
Wire Type: Copper Only
Wire Gauge: 22-16 AWG
Torque: 2kgf-cm (1.73 in-lbf)
ACI
4~20mA
Bias
Potentiometer
Full scale voltmeter
0 to 10 VDC
N PN mo de wi th e xte rna l p ow e r
2 4
+
Vdc
-
Fo rwa rd/St op
R eve rse /Sto p
R ese t
Mu lti -ste p 1
Mu lti -ste p 2
Mu lti -ste p 3
Factory Settings (NPN mode)
RA-RC
Resistive Load
5A(N.O.)/3A(N.C.) 277Vac;
5A(N.O.)/3A(N.C.) 30Vdc
Refer to P45 for programming.
RB-RC
Resistive Load
5A(N.O.)/3A(N.C.) 277Vac;
5A(N.O.)/3A(N.C.) 30Vdc
AVI
GND
MCM
MO1
+10V
Photo coupler
output
Factory setting:
fault indication
+2 4V
M0
M1
M2
M3
M4
M5
GN D
E
2-9

Advertisement

Table of Contents
loading

Table of Contents