PROBLEM
Controller displays
HEATING
FAILURE.
6.2.2 Error Messages and Display Problems
PROBLEM
Controller displays
low temp.
Controller displays
Hot hi-1.
Controller displays Hi
temp.
Controller displays
RECOVERY
FAULT/ YES and
alarm sounds.
Controller display is in
wrong temperature scale
(Fahrenheit or Celsius).
Controller displays
High limit
failure
disconnect
power.
Controller displays
TEMP PROBE
FAILURE
Controller displays
SERVICE
REQUIRED followed
by an error message.
PROBABLE CAUSES
blower.
Gas valve off, failed controller,
failed transformer, open high-limit
thermostat.
PROBABLE CAUSES
Frypot temperature has dropped
more than 30°F (17°C) lower than
setpoint in idle mode or 45°F (25°C)
in cook mode.
Frypot temperature is more than
410ºF (210ºC) or, in CE countries,
395ºF (202ºC).
Frypot temperature is more than 40
ºF (4ºC).
Recovery time exceeded maximum
time limit.
Incorrect display option
programmed.
A. Open drain valve
B. Failed high limit
Problem with the temperature
measuring circuitry including the
probe or damaged controller wiring
harness or connector.
An error has occurred which
requires a service technician.
CORRECTIVE ACTION
your FAS for service.
It is normal for this message to appear during
startup if the lines have air in them. Check that
the gas valve is on. If it continues, shut the fryer
down and call your FAS for assistance.
CORRECTIVE ACTION
This display is normal for a short while if a large
batch of frozen product is added to the frypot or if
the fryer is not heating properly. If the issue
persists call your FAS for assistance.
Shut the fryer down immediately and call your
FAS for assistance.
Press the power button to turn off fryer and let
cool before returning power to fryer. If issue
continues call your FAS for assistance.
Clear error and silence the alarm by pressing the 
(YES) button. Maximum recovery time is 2:25. If
the error continues call your FAS for assistance.
Fryers using the FilterQuick
between F° to C° by pressing the  button until
Product setup is displayed. Press  to scroll to
Tech Mode and press . Enter 1658. Press the
scan button. The controller displays OFF. Turn
the controller on to check temperature. If the
desired scale is not displayed, repeat.
A. Close the drain valve.
B. Shut the fryer down immediately and call your
FAS for assistance.
Shut the fryer down and call your FAS for
assistance.
Press the  (YES) button if the issue is fixed or
press the  (NO) button to continue cooking and
call your FAS for assistance. In some cases,
cooking may not be available.
6-3