The controller displays REMOVE PAN.
*NOTE: If the filter paper change time has expired, normally every 25
hours, the CHANGE FILTER PAPER? message repeats every 15
minutes instead of every four minutes.
6. Remove the pan. The controller display changes to CHANGE PAPER. Change the filter
paper and ensure the filter pan has been pulled forward, out of the cabinet for at least 30 seconds.
Once the pan has been out for 30 seconds the controller displays OFF. Ensure the pan is dry
and assembled correctly. Push the filter pan back into the fryer. Ensure "A" is displayed on the
MIB board.
7.
Switch the controller on. The controller displays the fryer temperature until the fryer reaches
setpoint.
8. If a filtration error occurs six consecutive times, the return valve closes and the controller
displays SERVICE REQUIRED alternating with YES and an alarm.
9. Press 
(YES)
to silence alarm and continue.
The controller displays SYSTEM ERROR and the error message for 15
seconds changing to SYSTEM ERROR FIXED alternating with YES
NO.
10. Press 
(NO)
to continue cooking. Call your FAS to repair and reset
the fryer. The error will be re-displayed every 15 minutes until the issue
is repaired. Semi-automatic filtration and auto top off is disabled until
the fryer is reset.

4.4.2 Clogged Drain Error

The clogged drain error occurs during auto filtration when the oil level sensor detects that oil has not
completely drained from the frypot. This may be due to a clogged drain or an oil sensor failure.
When this occurs the controller displays CLEAR DRAIN for 15 seconds changing to IS
DRAIN CLEAR? alternating with YES.
1. Clear debris from the drain using the fryer's friend and press the 
2. The controller displays DRAINING. Once the oil level sensor detects the oil has drained,
normal auto filtration operation resumes.

4.5 Filter Busy

When FILTER BUSY is displayed on the controller, the system is waiting on another vat to be
filtered or waiting on another issue to clear. Wait 15 minutes to see if problem is corrected. If not,
call your local FAS.