Reversing Timer Spin / Dwell Adjustments - ADC AD-30 Installation Manual

Hide thumbs Also See for AD-30:
Table of Contents

Advertisement

REVERSING TIMER SPIN / DWELL ADJUSTMENTS

Dual timer models with "reversing option" have an electric reversing timer in the electric service box, which is
located in the upper rear area of the dryer.
Both the dwell (stop) time and tumbler spin time are adjustable by mode selection switches located on the
electronic timer (as noted in the illustration below).
SPIN TIME
Adjustment Position Number
Time in
DWELL (STOP) TIME
Adjustment Position Number
Time in
* Values shown are +/- 1-second.
113063 - 11
SECTION IX
TIMING LEGEND
Seconds*
Seconds*
www.adclaundry.com
Counterclockwise - Clockwise
30 - 150
Counterclockwise - Clockwise
5 - 10
55