AD-35x2 and AD-35x2R
Installation Manual
WARNING: For your safety the
information in this manual must be
followed to minimize the risk of fire or
explosion and to prevent property
damage, personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Clear the room, building or area of
all occupants.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
AVERTISSEMENT: Assurez-vous de
bien suivre les instructions données dans
cette notice pour réduire au minimum le
risque d'incendie ou d'explosion ou pour
éviter tout dommage matériel, toute
blessure ou la mort.
—Ne pas entreposer ni utiliser d'essence
ni d'autres vapeurs ou liquides
inflammables à proximité de cet
appareil ou de tout autre appareil.
—QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ:
Ne pas tenter d'allumer d'appareils.
Ne touchez à aucun interrupteur. Ne
pas vous servir des téléphones se
trouvant dans le bâtiment.
Évacuez la pièce, le bâtiment ou la
zone.
Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le
fournisseur de gaz, appelez le service
des incendies.
—L'installation et l'entretien doivent être
assurés par un installateur ou un
service d'entretien qualifié ou par le
fournisseur de gaz.
American Dryer Corporation
88 Currant Road
Fall River MA 02720-4781 USA
Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447
e-mail: techsupport@amdry.com
www.amdry.com
ADC Part No. 113297- 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AD-35x2 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADC AD-35x2

  • Page 1 American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 USA Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447 e-mail: techsupport@amdry.com www.amdry.com ADC Part No. 113297- 1...
  • Page 2 Replacement parts can be obtained from your reseller or the ADC factory. When ordering replacement parts from the factory, you can FAX your order to ADC at +1 (508) 678-9447 or telephone your order directly to the ADC Parts Department at +1 (508) 678-9000. Please specify the dryer model number and serial number in addition to the description and part number, so that your order is processed accurately and promptly.
  • Page 3: Table Of Contents

    WARNING In the State of Massachusetts, the following installation instructions apply: Proposition 65 Installations and repairs must be performed by a qualified or licensed contractor, plumber, or Use of this product could expose you to gasfitter qualified or licensed by the State of substances from fuel combustion that contain Massachusetts.
  • Page 4: Safety Precautions

    Safety Precautions ___________________ WARNING WARNING The collection of lint in the burner area and exhaust ductwork can create a potential fire hazard. For your safety, the information in this manual must be followed to minimize the risk of fire or explosion For personal safety, the dryer must be electrically grounded or to prevent property damage, personal injury, or loss in accordance with local codes and/or the National Electrical...
  • Page 5: Specifications

    Specifications _____________________________________________________________________ MAXIMUM CAPACITY (DRY WEIGHT) 35 lb 15.88 kg PER POCKET 76.2 cm TUMBLER DIAMETER 30” 76.2 cm TUMBLER DEPTH 30” 347.4 L TUMBLER VOLUME 12.27 cu ft PER POCKET 0.19 kW TUMBLER / DRIVE MOTOR 1/4 hp PER POCKET BLOWER / FAN MOTOR 1/2 hp 0.37 kW...
  • Page 6: Installation Procedures

    Installation Procedures ______________ Dryer must be exhausted to the outdoors in an area where correct exhaust venting can be achieved as noted in this Installation should be performed by competent technicians in manual (refer to Exhaust Requirements section). accordance with local and state codes. In the absence of Dryer must be located in an area where correct exhaust venting these codes, the installation must conform to applicable can be achieved as noted in this manual (refer to Exhaust...
  • Page 7: Fresh Air Supply Requirements

    Fresh Air Supply Requirements ______ Exhaust Requirements IMPORTANT: Dryer should be located where a minimum When the dryer is operating, it draws in room air, heats it, amount of exhaust duct will be necessary. passes this air through the tumbler, and exhausts it out of the building.
  • Page 8 IMPORTANT: The dryer exhaust duct must not be This calculation of 10 feet (3.0 meters) compensates or allows connected to any gas vent, chimney, wall, ceiling, or for the use of a maximum of two elbows. Refer to the illustration concealing space of a building.
  • Page 9: Electrical Information

    Multiple Dryer (Common) Venting Each dryer should be connected to an independently protected branch circuit (each pocket can be independently wired, if you If it is not feasible to provide separate exhaust ducts for each prefer). The dryer must be connected with copper wire only. dryer, ducts from individual dryers may be channeled into a Do not use aluminum wire, which could cause a fire hazard.
  • Page 10: Gas Information

    Grounding Gas Information A ground (earth) connection must be provided and installed in It is your responsibility to have all plumbing connections made accordance with state and local codes. In the absence of by a qualified professional to ensure that the gas plumbing these codes, grounding must conform to applicable installation is adequate and conforms to local and state requirements of the National Electrical Code ANSI/NFPA NO.
  • Page 11: Preparation For Operation / Start-Up

    Technical Gas Data IMPORTANT: Pipe joint compounds that resist the action of natural gas and L.P. gas must be used. Gas Specifications Test all connections for leaks by brushing on a soapy water Type of Gas solution (liquid detergent works well). Manifold Pressure* In-Line Pressure...
  • Page 12: Preoperational Test

    Check bolts, nuts, screws, terminals, and fittings for tightness. The dryer should be operated through one complete cycle to ensure that no further adjustments are necessary and that all Gas Models – be sure that all gas shutoff valves are in the components are functioning properly.
  • Page 13: Parts

    NOTE: When ordering replacement parts from the reseller All returns should be shipped to the ADC factory in such a or the manufacturer, be sure to give them the correct model manner that they are insured and a proof of delivery can be number and serial number so that your parts order can be obtained by the sender.
  • Page 14: Adjustments

    When contacting ADC, please have the A back draft damper that is sticking partially closed can model number and serial number available.
  • Page 15: Procedure For Functional Check Of Replacement Components

    Procedure for Functional Check of Replacement Components ________ Notes ______________________________________________________ DSI Module Theory of Operation: Start the drying cycle. When the gas ___________________________________________________________ burner ignites within the chosen trial for ignition time (8-seconds), the flame sensor detects gas burner flame and ___________________________________________________________ signals the DSI module to keep the gas valve open as long as there is a call for heat.
  • Page 16 ADC Part No. 113297 1 - 07/25/12...