WARNING: For your safety the information
in this manual must be followed to
minimize the risk of fire or explosion and
to prevent property damage, personal
injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Clear the room, building or area of
all occupants.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
— Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.
Phase 5 / DMC
—Ne pas entreposer ni utiliser d'essence
—QUE FAIRE SI VOUS SENTEZ UNE
—L'installation et l'entretien doivent être
Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette
notice pour réduire au minimum le risque
d'incendie ou d'explosion ou pour éviter
tout dommage matériel, toute blessure ou
la mort.
ni d'autres vapeurs ou liquides
inflammables à proximité de cet
appareil ou de tout autre appareil.
ODEUR DE GAZ:
Ne pas tenter d'allumer d'appareils.
Ne touchez à aucun interrupteur. Ne
pas vous servir des téléphones se
trouvant dans le bâtiment.
Évacuez la pièce, le bâtiment ou la
zone.
Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le
fournisseur de gaz, appelez le service
des incendies.
assurés par un installateur ou un
service d'entretien qualifié ou par le
fournisseur de gaz.
American Dryer Corporation
88 Currant Road
Fall River MA 02720-4781 USA
e-mail: techsupport@amdry.com
www.adclaundry.com
ADC Part No. 112175-9

Advertisement

Table of Contents
loading

Summary of Contents for ADC AD-333

  • Page 1 AD-333 Installation Manual Phase 5 / DMC AVERTISSEMENT: Assurez-vous de bien WARNING: For your safety the information suivre les instructions données dans cette in this manual must be followed to notice pour réduire au minimum le risque minimize the risk of fire or explosion and d’incendie ou d’explosion ou pour éviter...
  • Page 2 Replacement parts can be obtained from your reseller or the ADC factory. When ordering replacement parts from the factory, you can FAX your order to ADC at +1 (508) 678-9447 or telephone your order directly to the ADC Parts Department at +1 (508) 678-9000. Please specify the dryer model number and serial number in addition to the description and part number, so that your order is processed accurately and promptly.
  • Page 3: Table Of Contents

    WARNING In the State of Massachusetts, the following installation instructions apply: Proposition 65 Installations and repairs must be performed by Use of this product could expose you to a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the State of substances from fuel combustion that contain Massachusetts.
  • Page 4: Safety Precautions

    Safety Precautions ___________________ A program should be established for the inspection and cleaning of lint in the burner area, exhaust ductwork, and WARNING area around the back of the dryer. The frequency of inspection and cleaning can best be determined from experience at each location.
  • Page 5 CE ONLY IMPORTANT: This appliance must only be installed and operated in the country of destination indicated on the dryer’s data plate. If the appliance is to be installed and operated in a country other than the one indicated on the data plate, a data plate amendment must be obtained from American Dryer Corporation.
  • Page 6: Specifications

    Specifications _____________________________________________________________________ 13.60 kg MAXIMUM CAPACITY 30 lb (DRY WEIGHT) PER POCKET 69.21 cm TUMBLER DIAMETER 27-1/4” TUMBLER DEPTH 30” 76.20 cm 286 L TUMBLER VOLUME 10.1 cu ft PER POCKET TUMBLER/DRIVE MOTOR 1/2 hp 0.37 kW PER POCKET BLOWER/FAN MOTOR N / A PER POCKET 54.61 cm...
  • Page 7 Specifications _____________________________________________________________________ NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. 112175 - 9 www.adclaundry.com...
  • Page 8: Installation Procedures

    Installation Procedures ______________ Dryer must be exhausted to the outdoors in an area where correct exhaust venting can be achieved as noted in this Installation should be performed by competent technicians manual (refer to Exhaust Requirements section). in accordance with local and state codes. In the absence of Dryer must be located in an area where correct exhaust these codes, the installation must conform to applicable venting can be achieved as noted in this manual (refer to...
  • Page 9: Fresh Air Supply Requirements

    Fresh Air Supply Requirements ______ Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will create This appliance may only be installed in a room that meets excessive back pressure, which results in slow drying, the appropriate ventilation requirements specified in the increased use of energy, overheating of the dryer, and national installation regulations.
  • Page 10 Single Dryer Venting (8-Inch Duct) If the length of the duct run or quantity of elbows used exceeds the above noted specifications, the cross-sectional IMPORTANT: A minimum exhaust duct size of 8-inches area of the ductwork may need to be increased. (20.3 cm) must be used.
  • Page 11: Electrical Information

    Electrical Information ________________ Electrical Service Specifications Gas Models Only Electrical Requirements All electrical connections must be made by a properly ELECTRICAL SERVICE SPECIFICATIONS (PER POCKET) licensed and competent electrician. This is to ensure that IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When the electrical installation is adequate and conforms to local ordering, specify exact voltage.
  • Page 12: Gas Information

    Single-Phase (1ø) Wiring Connections/Hookup IMPORTANT: Failure to isolate or disconnect the dryer from supply as noted can cause irreparable damage to The electrical input connections on all single-phase (1ø) the gas valve voiding the warranty. gas dryers are made into the junction box located at the top left rear area of the dryer (refer to page 7).
  • Page 13 Natural Gas Piping Connections Regulation is controlled by the dryer’s gas valve’s internal All components/materials must conform to National Fuel regulator. Incoming supply pressure must be consistent Gas Code Specifications ANSI Z223.1-LATEST EDITION, or between a minimum of 6.0 in WC (14.92 mb) and a maximum in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/ of 12.0 in WC (29.9 mb) pressure.
  • Page 14: Preparation For Operation / Start-Up

    Preparation for Operation / Start-Up _ IMPORTANT: When plumbing upper and lower tumblers together, as illustrated on previous page, supply The following items should be checked before attempting connection must be a minimum of 3/4” (19.05 mm). to operate the dryer: An 1/8”...
  • Page 15: Preoperational Instructions

    Shutdown Instructions _______________ IMPORTANT: There is no regulator provided in an L.P. dryer. The water column pressure must be regulated at If the dryer is to be shutdown (taken out of service) for a the source (L.P. tank) or an external regulator must be period of time, the following must be performed: added to each dryer.
  • Page 16: Routine Maintenance

    IMPORTANT: No replacements, credits, or refunds will be issued for merchandise damaged in transit. WARNING All returns should be shipped to the ADC factory in such a manner that they are insured and a proof of delivery can be To avoid the hazard of electrical shock, discontinue obtained by the sender.
  • Page 17: Adjustments

    ADC. This information is on the data label affixed to the right side panel area at the rear of the dryer. When contacting ADC, please have the model number and serial number available. 1. Model Number – This describes the style of dryer and type of heat (gas, electric, or steam).