BURNER AND TUMBLER / LINT CHAMBER
MANUAL RESET HI-LIMIT INSTRUCTIONS
MANUAL RESET HI-LIMIT INSTRUCTIONS
FOR MECHANICAL METER, TIMER OR PHASE 5 WITHOUT HEAT FAULT
This dryer was manufactured with a burner manual reset hi-limit and tumbler/lint chamber hi-limit thermostat.
If either burner manual reset hi-limit thermostat is open prior to the start of the drying cycle, or during the cycle,
the dryer will not recognize the open state of the burner hi-limit thermostat and will start or continue through the
drying cycle with no heat. Manual reset hi-limit thermostat must be reset manually.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow, or improper burner
oven operation.
The location of the manual reset hi-limit switch is on the right side of the burner box.
58
SECTION XI
IMPORTANT

(GAS MODELS ONLY)

IMPORTANT
This dryer is equipped with a burner
hi-limit and tumbler/lint chamber hi-limit
thermostat which must be reset manually.
WARNING: Discontinue power to dryer
before attempting to reset hi-limit.
American Dryer Corp.
ADC P/N:114093
113063 - 11