Connection Via Icn Connector - Lenze M55BH063S04 Mounting And Switch-On Instructions

Ie2/ie3 bevel geared
Table of Contents

Advertisement

Connection via ICN connector

Position of the connections
Position
Meaning
1
ICN-M23 connector, 6-pole
• Power connection
• Brake connection
• PE connection
In addition to ICN-M23 connector , 8-pole:
• Motor temperature monitoring connection TKO or PT1000
2
ICN-M23 connector
• Feedback connection
• PT1000 temperature sensor connection
3
ICN-M17 connector
• Blower connection
Power and brake connection
ICN-M23 connector assignment
6-pole
ICN M23 6-pole
Contact
1
2
PE
4
5
6
2
2
1
+
6
5
4
Name
BD1
BD2
PE
U
V
W
Electrical installation
3
1
Note
-
If feedback is present, the PT1000 temperature sensor is wired in
the feedback connector.
-
If required, the terminal box can be rotated step by step by 90 °
after loosening the screws in the terminal box.
Meaning
DC +/AC brake
DC -/AC brake
PE conductor
Power phase U
Power phase V
Power phase W
Motor connection
Connection via ICN connector
43