Connection Via Terminal Box - Lenze M55BH063S04 Mounting And Switch-On Instructions

Ie2/ie3 bevel geared
Table of Contents

Advertisement

Electrical installation
Motor connection

Connection via terminal box

Connection via terminal box
Observe the notes on wiring, data on the nameplate, and the connection diagram in the
terminal box.
The connection must ensure a continuous and safe electrical supply:
No protruding wire ends
Use assigned cable end fittings
Ensure good electrical conductivity of the contact (remove paint residues) if an additional
PE connection is used
Establish a safe protective earth connection
After the connection is completed, make sure that all connections on the terminal board
are firmly tightened
The terminal box has to be free of foreign bodies, dirt, and humidity
All unused cable entries and the terminal box itself must be sealed so that they are dust-
tight and waterproof
The smallest air gaps between uncoated, live parts and against earth must not fall below the
following values:
Minimum requirements for basic insulation
according to IEC/EN 60664-1 (CE)
3.87 mm
Position of the connections
Note
Meaning
1
Power connection
Brake connection
PE connection
Feedback connection
Connection of temperature monitoring
2
Blower connection
38
Higher requirements for UL design
6.4 mm
9.5 mm
2
1
Note
If required, the terminal box cover can be rotated step by step by
90 ° after loosening the screws on the terminal box.
Motor diameter
<178 mm
> 178 mm