INSTALLATION

CAUTION
Finished flooring should be protected with
appropriate material to avoid damage from
moving the unit.
If unit is built into cabinetry, allow clearance for
unit to be removed from opening for potential
future service requirements.
If unit has been laid on its back or sides, place
unit upright and allow minimum of 24 hours
before connecting power.
1..Plug.the.unit.into.the.15.amp.grounded.outlet.
located.in.the.installation.opening..With.power.
applied.to.the.unit,.check.that.lighting.and.
cooling.function.operate.properly,.then.turn.off.
power.to.the.wall.outlet.at.the.circuit.breaker.
WARNING
Shut off power to the wall outlet before
installing unit into the opening.
2..Check.that.the.following.are.level.and.square:.
-.front.face.and.interior.opening.
-.installation.opening.and.floor.surface.
-.countertop.bottom.front.edge.
IMPORTANT: The.floor.under.the.unit.must.be.at.
the.same.level.as.the.surrounding.finished.floor.
3..If.all.surfaces.are.level,.refer.to.Figure.3.and.
perform.the.following:.
A..Measure.from.the.floor.to.the.bottom.of.the.
front.edge.of.the.countertop..
B..Measure.the.rear.of.unit.cabinet.from.floor.to.
top.of.cabinet,.at.back.corners..
C..Adjust.rear.legs.so.B.measurement.equals.A.
measurement..Using.an.adjustable.wrench.
or.pliers,.turn.legs.counterclockwise.to.raise.
the.unit.or.clockwise.to.lower.the.unit.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice
18" SHALLOW DEPTH SERIES
Operation / Installation Manual
IMPORTANT: Leveling. legs. should. not. extend.
more.than.3/4".from.bottom.of.unit.
4..Slide.unit.into.position..Make.sure.the.rear.
levelling.legs.slide.under.the.anti-tip.brackets..
Push.the.unit.into.the.opening.until.the.door.is.
flush.with.the.surrounding.cabinetry,.or.until.the.
rear.legs.are.tight.against.the.anti-tip.brackets.
IMPORTANT: The.rear.levelling.legs.must.be.
engaged.under.the.anti-tip.brackets..
5..Shim.the.front.of.the.unit.so.the.front.door.is.
flush.with.the.surrounding.cabinetry..Adjust.
the.front.legs.to.support.the.countertop.at.
the.shimmed.height..Using.an.adjustable.
wrench.or.pliers,.turn.legs.counterclockwise.
to.raise.the.unit.or.clockwise.to.lower.the.unit..
Countertop.should.be.resting.on.top.of.the.unit..
IMPORTANT: The.rear.levelling.legs.must.be.
engaged.under.the.anti-tip.brackets..
To prevent damage to the countertop and
unit underneath, do not place heavy objects
on
countertop
6..Check.interior.door.openings.inside.unit.to.
ensure.unit.is.level.
7
.
CAUTION
directly
above
the
unit.