Checking Product Temperature
To.accurately.check.the.temperature.of.the.product.
stored. in. a. refrigerated. compartment,. insert. an.
accurate.thermometer.into.a.sealable.plastic.(non-
breakable).bottle,.partially.filled.with.water..Tighten.
the.cap.securely.
Place.the.bottle.into.the.desired.area.for.24.hours.
Refrain.from.opening.the.unit.during.testing.period..
After.24.hours,.check.the.temperature.of.the.water..
Adjust.the.control.settings.if.necessary.and.re-test.
The.units.are.pre-set.to.achieve.the.recommended.
temperature. range. when. installed. in. a. 70°F.
ambient. environment.. Factors. which. affect. the.
internal. temperatures. of. the. cabinet. include. the.
following:
. ■ Temperature.setting.
. ■ Room.temperature.where.installed.
. ■ Number.of.times.the.door.is.opened.and.
closed.
. ■ Length.of.time.door.is.left.opened.
. ■ Adjacent.compartment.temperature.
. ■ Style.of.door.installed.
. ■ Door.gasket.and.sealing.
. ■ Amount.of.time.internal.light.is.illuminated.
. ■ Installation.in.direct.sunlight.or.near.a.heat.
source.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice
18" SHALLOW DEPTH SERIES
Operation / Installation Manual

MAINTENANCE

Shut off the electricity to the unit before
cleaning the condenser and other routine
maintenance.
Cleaning
To.clean.stainless.steel.exterior.or.interior.surfaces,.
use.a.soft,.non-abrasive.stainless.steel.cleaner.to.
wipe.down.the.surfaces.
Glass. doors. can. be. cleaned. using. any. standard.
glass.cleaner.available.on.the.market.
To. clean. interior. non-metallic. surfaces. and.
removable. parts,. wash. with. a. mild. solution. of.
soap.and.lukewarm.water.with.a.little.baking.soda..
Rinse.and.dry.thoroughly..Avoid.getting.water.on.
lights,.control.panel,.and.fan.motor.
Do not use abrasive cleaners or cloths on any
of the interior or exterior surfaces or removable
parts.
Cleaning the Condenser
The. condenser. should. be. cleaned. every. three. .
months..The.condenser.is.located.behind.the.toe.
plate..Remove.the.toe.plate.and.use.a.soft.bristle.
brush.and.vacuum.to.remove.dust.and.lint..Avoid.
damaging.or.crushing.the.condenser.fins.or.tubing..
Upon.completion,.re-install.the.toe.plate.
Failure to clean the condenser could result in
temperature loss or mechanical failure. Clean
this area every three months.