6
=
50 ms
h
7
=
100 ms
h
8
=
200 ms
h
9
=
500 ms
h
A
=
1 s
h
B
=
2 s
h
C
=
5 s
h
D
=
10 s
h
E
=
20 s
h
F
=
50 s
h
Example: It is wished to program the following waveform:
1 s
10.00 V
3 s
30.00 V
100 ms
25.67 V
200 us
2.00 V
It is also wished to repeat this sequence 10 times.
The required data table is as follows:
ABT:A10.00_B30.00_A30.00_725.67_002.00 _002.00_N10 or
ABT A10.00_B30.00_A30.00_725.67_002.00_002.00_N10
RUN/STP
Format:
RUN
Function: Starts waveform generation in ARB mode
Format:
STP
Function : Interrupts the arbitrary function while running.
2 x 100 μs 2.00V
100 ms 25.67 V
2 s+1 s 30.00 V
1 s 10.00 V