Power Supply Connection And Cut Off; Power Connection - Jolly LP-H400 User Manual

Table of Contents

Advertisement

The projector can be placed directly on the stage floor or rigged in any orientation on atruss without alte-
ring its operation characteristics.
For overhead use,always install a safety-rope that can hold at least 10 times the weight of the fixture.You
must only use safety-ropes with screw on carabines.Pull the safety-rope through the two apertures on the
bottom of the base and over the trussing system etc.

4.3 Power supply connection and cut off

Connect the light source to the main power source with the plug of the power cord, or cut off the power
supply:
Connection: according to procedures, the power plug and socket is inserted into
the groove one one alignment,rotation.
Cut off:according to procedures,press the button on the rotating plug,pull out.
Warning: The maximum connecting is
less than 4 pcs to make sure the normal life
time of the lighting fixture.

4.4 Power Connection

If you wish to change the power supply settings, see the chapter appendix Connect the fixture to the
mains with the enclosed power cable and plug.
CABLE(EU)
Brown
Light blue
Yellow/Green
Warning: it is necessary to make sure that
the installation location is perfectly appropriate,
and the installation location is safe and reliable.
CABLE(US)
Black
Live
White
Neutral
Green
Earth
- 5 -
2
1
3
Pin
INTERNATIONAL
L
N
2
1

Advertisement

Table of Contents
loading