Advertisement

Quick Links

USER MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Jolly X-1000 Spot

  • Page 1 USER MANUAL...
  • Page 3: Table Of Contents

    Table of content 1.Open-Package guidelines............... 1.1Package....................1 2.Safety instructions..................1 3.Operating determination.................3 4.Rigging the fixture...................4 4.1 Mounting.....................4 4.2Installing the Clamps................4 4.3 Power supply connection and cut off...........6 4.4 Power Connection................6 4.5 DMX-512 connection/connection between fixtures......6 Description of the device............
  • Page 4 Congratulations on choosing our products! Please carefully read this instruction manual in its entirety and keep it well for using reference. This manual contained about the installation and the relative using information of this products. Plese refere this manual's relative instruction when using this equipment.
  • Page 5: Open-Package Guidelines

    1.Open-Package guidelines This equipment is made of new style,high intensity plastic.It fully shows the modem times light charac teris- tic with teristic with beauty struture. And it is made accord to CE standard. Fully agree with the internation standard of DMX 512 agreement.
  • Page 6 Never let the power-cord come into contact with other cables! Handle the power cord and all connections with particular caution! Make sure that the available voltage is not higher than stated on the rearpanel. Always plug in the power plug least. Make suer that the power-switch is set to off-position before you con ections with themains with particular caution! Make sure that the power-cord is never crimped or damaged by sharp edges.Check the decice and the p- ower-cord from time to time.
  • Page 7: Operating Determination

    lines of the projectors from indirect contact and/orshorting to earth by using appropriately sized residual current devices. Disposing This product is supplied in compliance with European Directive 2012/19/EU-Waste Electrical and Electronic Equipment (WEEE). To preserve the environment please dispose/recycde this product at the end of its life according to the local regulation.
  • Page 8: Rigging The Fixture

    4.Rigging the fixture 4.1 Mounting Pay attention to the regulations of CE. Installation by qualified staff to complete. For the various mounting positions of the FIXTURE(standing on the floor, sideways or hanging different accessories kits are available. Through this a safe and firm installation is assured. You’ll find special connectors on the bottom side of the system which are put to use here.
  • Page 9 The projector can be placed directly on the stage floor or rigged in any orientation on atruss without alte- ring its operation characteristics. For overhead use,always install a safety-rope that can hold at least 10 times the weight of the fixture.You must only use safety-ropes with screw on carabines.Pull the safety-rope through the two apertures on the bottom of the base and over the trussing system etc.
  • Page 10: Power Supply Connection And Cut Off

    4.3 Power supply connection and cut off Connect the light source to the main power source with the plug of the power cord, or cut off the power supply: Connection: according to procedures, the power plug and socket is inserted into the groove one one alignment,rotation.
  • Page 11: Description Of The Device

    DMX Terminator Diagram -For installations where the DMX cable has to run a long distance or is In an electrically noisy environment it is recommended to use a DMX terminator. This help in preventing corruption of the signal by electrical noise. The DMX terminato r is simply an XLR plug witha Ω...
  • Page 12: Dimension

    6.Dimension - 8 -...
  • Page 13: Display Control

    7.Display control 7.1 Navigation in the Menu Using the buttons or touch screen, and this can be simply and easily set the address code and functions code. If you view or modify the lighting feature set, then press ENTER button, the display will enter the menu interface.
  • Page 14 Click on the main interface of the icon, numerical to view view Settings related information of lamps and lanterns.Symbols such as the main interface appear “ “,the following error message indicates that there might be a lamps and lanterns,can click to view and control information content to modify the lamps and lanterns.
  • Page 15: Menu Maps

    7.3 Menu Maps Dmx Address 001~xxx Dmx Address Mode1 1-26 Setup Channel Mode Default Mode1 Mode2 1-26 Mode3 1-34 Fixture Id 0001-xxxx Lamps address Fixture Times xxxxxh xxm Total working hours Lamp Times Xxxxh xxm Lamp On working hours Error List Exx xxxxxx Error details Information...
  • Page 16: Dmx Protocol

    8.DMX protocol Mode1 Mode2 Mode3 Function DMX Value Pan,16-bit (MSB and LSB) 0-65535 Left → right (32768 = neutral) Tilt,16-bit (MSB and LSB) 0-65536 Up → down (32768 = neutral) Colour Wheel Continuous Scroll Open Open→Slot1 1-14 Slot1 Slot1→Slot2 16-29 Slot2 Slot2→Slot3 31-44...
  • Page 17 Mode1 Mode2 Mode3 Function DMX Value Gobo 2 40-44 Gobo 3 45-49 Gobo 4 50-54 Gobo 5 55-59 Gobo shake Gobo 1, 360° slow →10° fast 60-89 Gobo 2, 360° slow →10° fast 90-119 Gobo 3, 360° slow →10° fast 120-149 Gobo 4, 360°...
  • Page 18 Mode1 Mode2 Mode3 Function DMX Value Open Open → Gobo 1 Gobo 1 Gobo 1 → Gobo 2 11-19 Gobo 2 Gobo 2 → Gobo 3 21-29 Gobo 3 Gobo 3 → Gobo 4 31-39 Gobo 4 Gobo 4 → Position 5 41-49 Position 5 Position 5 →...
  • Page 19 Mode1 Mode2 Mode3 Function DMX Value CCW rotation, slow→fast 130-253 Prism stop, indexed at 45° 254-255 Frost No frost → full fros 0-255 Iris Close 252-255 Fast open,fast close -fast open,fast close 172-211 Slow open,slow close- fast open,fast close 212-251 Slow pulsation fast pulsation 132-171 Open →closed...
  • Page 20: Maintance And Cleaning

    9.Maintance and cleaning DANGER:Disconnect from the mains before starting any maintenance work. It is absolutely essential that the fixture is kept clean and that dust,dirt and smoke fluid residues must not buildup on or within the fixture. Otherwise, the fixtures light-output will be significantly reduced. Regular cleaning will not only ensure the maximum light-output, but will also allow the fixture to function reliably through out its life.
  • Page 21: Menu Function

    10.4 Menu Function Touch screen,English menu. 2.Each DMX Value displayable. 3.Monitor could ON/OFF automatically. 4.Show fixture, lamp use time. 5.Lamp on/off when power on. 6.Screen rotation. 7.Auto error detection. 8.Wireless input,wired input,wirelss in/xlr out. 10.5 light table ° 60 Illuminance(Lux) 1730 °...
  • Page 22: Gobo Whee

    10.7 Gobo wheel RGOBO WHEEL 一 RGOBO WHEEL 二 - 18 -...
  • Page 23 GOBOR WHEEL - 19 -...
  • Page 24: Electronic Drawing

    11.Electronic drawing Gobo Module Driver Board Focus Module Driver Board CMY Module Driver Board Switch Switch Switch Gobo Seetting Seetting Wheel Blower Blower Seetting Blower Fan 1 Fan2 Rotating Static Rotating Colour Gobo Gobo Gobo Gobo Gobo Shutter Shutter Frost Prism Prism Cyan...
  • Page 26 ht tp: //www.jol lyl ight ing. com Guangzhou hongcai stage equipment Co.,Ltd Tel:+862084558833 Fax:+862084559699 Email:info@jollylighting.com P.C:511450 Add:Building2,No.32,Changsha Street,Shachong Village,shiji Tow.Panyu District,Guangzhou,China...

This manual is also suitable for:

X-1000 spot pf

Table of Contents