4.3 Power supply connection and cut off
Connect the light source to the main power source with the plug of the power cord, or cut off the power
supply:
Connection: according to procedures, the power
plug and socket is inserted into the groove one one
alignment,rotation.
Cut off:according to procedures,press the button
on the rotating plug,pull out.
4.4 Power Connection
If you wish to change the power supply settings, see the chapter appendix Connect the fixture to the
mains with the enclosed power cable and plug.
CABLE(EU)
Brown
Light blue
Yellow/Green
4.5 DMX-512 connection/connection between fixtures
Only use stereo shieded cable and 3-pin XLR-plugs and connectors in order to connect.
Caution
At the last fixture,the DMX-cable has to be terminated with a terminatou. solder a 120 resistor between
signal(-) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.
DMX output
DMX iutput
3-pin XLR socket
3-pin XLR socket
2
1
3
CABLE(US)
Black
White
Green
1:Ground
2:Signal(-)
2
1
2
1
3:Signal(+)
3
3
Warning: please verify the power of the power
supply equipment prior to the connection! Earth wire
must be grounded!
Pin
INTERNATIONAL
Live
Neutral
Earth
DMX output
5-pin XLR socket
5
5
1
1
4
2
4
2
3
3
- 6 -
2
1
2
1
3
L
N
DMX iutput
5-pin XLR socket
1:Ground
2:Signal(-)
5
5
1
1
3:Signal(+)
4
2
4
2
4:N.A.
3
3
5:N.A.