Technical Data; Installation Compliance - enware DET5071A-CNBSN Installation And Maintenance Instructions Manual

Wall mounted sensor tap - hands-free - active sense with custodian basin spout
Table of Contents

Advertisement

technical data

Inlet Connection
Recommended Working Pressure Range
Flow Rate
(Aerator supplied standard with a spout)
Maximum Hot Water Supply Temperature
Operating Voltage
Maximum Current
Power Consumption
Sensor Min / Max Ambient Temperature
Sensor Protection Rating
Sensor Range
Flow time
Optional program settings are available on the following:
• Adjust Minimum Flow Time (Afterflow)
• Adjust Maximum Flow Time
• Adjust Sensor Range
The optional settings are available at the time of ordering. Contact Enware for more details.

installation compliance

*Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and
AS/NZS3500. Installations not complying with PCA and AS/NZS 3500 may void the product and
performance warranty provisions.
Reference should also be made to the Australasian Health Facility Guidelines (AHFG), ABCB and
Local Government regulations when considering the choice of, and the installation of these
products.
This product must be installed and commissioned by a qualified plumber.
For use with potable water only.
NOTE: Enware Australia advises:
1. Due to ongoing Research and Development, specifications
may change without notice.
2. Component specifications may change on some export
models.
www.enware.com.au
15mm (1/2" BSP)
100 - 500 kPa*
8 lpm supplied standard.
5 lpm available on request.
70 °C *
24V DC
1A
Less than 10W
Minimum: -5 °C, Maximum: 50 °C
IP67 for the front panel and sensor lens.
No IP rating behind panel.
100 - 235mm
Runs as long as hand is within range. (Active Sense)
When out of range, runs for 6 seconds. (Afterflow)
Maximum continuous flow period per sensor
activation is 45 seconds. (Security Time Out)
• Purge Flush Running Time
• Purge Flush Period Frequency
• Mode – On /Off Demand or Active Sense
The more
stars the more
water efficient
WATER RATING
www.waterrating.gov.au
8
litres per
minute
Call 1300 369 273
3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DET5071A-CNBSN and is the answer not in the manual?

Table of Contents