Wiring example
When the Gate Suppress function is utilized, connect the drive to a safety certified
interrupting device utilizing EDM output signal to reconfirm both safety inputs GS1 and
GS2. Follow the wiring instructions in the Instruction manual.
Safety input
Safety Switch
(Example: emergency
push button)
(*) Specification of the fuse:
The arch extinguishing fuse with rated voltage AC250V, rated current 100mA complies to either IEC6127 -2/-3/-4
example) SOC
Little
Any external signal voltage connected to the WL200 must be from a SELV Power Supply.
By pressing the emergency stop button, the current to GS1 and GS2 is shut off, and the
inverter output is shut off. By this, motor is free-running. This behavior is according to the
stop category 0 defined in EN60204.
Note 1: Above is the example to use the intelligent input terminal with source logic. When
it is used with sink logic, the wiring is to be modified.
Note 2: The wire for safety relay and emergency input signal are to be shielded coaxial
cable for example RS174/U (produced by LAPP) by MIL-C17, or KX2B by NF C
93-550 with diameter 2.9mm with less than 2 meters. Please be sure to ground
the shielding.
Note 3: All the inductance related parts such as relay and contactor are required to
contain the over-voltage protection circuit.
Reset
EDM
Switch
(feedback) input
T31
T32
T33
T11
T12
T21
T22
EQ series AC250V, 100mA (UL, SEMKO, BSI)
216 series AC250V, 100mA (CCC, UL, CSA, SEMKO, CE, VDE)
Fuse *
+24V
A1
+24V
A2
Safety output
S14
S24
Safety Unit
※Standard
(IEC61508, ISO13849)
certified
90
CM2
EDM
GS1
GS2
PLC
WL200
L
M
KM1